Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.

نویسندگان

  • Kristin A Freund
  • Nina R Kieves
  • Juliette L Hart
  • Sasha A Foster
  • Unity Jeffery
  • Felix M Duerr
چکیده

OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based applications (novel goniometers A and B), a digital goniometer (novel goniometer C), and a UG; 3 evaluators performed measurements in triplicate for each angle with each device. Results were compared with stifle joint angle measurements on radiographs (used as a gold standard). Accuracy was determined by calculation of bias and total error, coefficients of variation were calculated to estimate reliability, and strength of linear association between radiographic and goniometer measurements was assessed by calculation of correlation coefficients. RESULTS Mean coefficient of variation was lowest for the UG (4.88%), followed by novel goniometers B (7.37%), A (7.57%), and C (12.71%). Correlation with radiographic measurements was highest for the UG (r = 0.97), followed by novel goniometers B (0.93), A (0.90), and C (0.78). Constant bias was present for all devices except novel goniometer B. The UG and novel goniometer A had positive constant bias; novel goniometer C had negative constant bias. Total error at 50° and 100° angles was > 5% for all devices. CONCLUSIONS AND CLINICAL RELEVANCE None of the devices accurately represented radiographically measured stifle joint angles. Additional veterinary studies are indicated prior to the use of novel goniometers in dogs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of position measurement for 6R robot using magnetic encoder AS5045

Recording the variation of joint angles as a feedback to the control unit is frequent in articulated arms. In this paper, magnetic sensor AS5045, which is a contactless encoder, is employed to measure joint angles of 6R robot and the performance of that is examined. The sensor has a low volume, two digital outputs and provides a high resolution measurement for users; furthermore its zero positi...

متن کامل

Psychometric properties of measurement tools for quantifying knee joint position and movement: a systematic review.

This systematic review critically evaluates literature on the reliability and validity of measurement tools for quantifying knee joint angles and knee movement. A search was conducted of seven medical databases and one biomedical engineering database, yielding 43 articles that reported reliability or validity. Tools for quantifying knee joint angles included standard handheld goniometers, fluid...

متن کامل

Radiographic landmarks for measurement of cranial tibial subluxation in the canine cruciate ligament deficient stifle.

OBJECTIVES The primary objective was to develop a repeatable radiographic technique for assessment of cranial tibial subluxation (CTS) and test the intra-observer and inter-observer repeatability of the chosen landmarks. A secondary objective was to determine the effects of digital radiographic magnification on CTS measurement repeatability. METHODS Twenty-three normal canine pelvic limbs wer...

متن کامل

A Non-Contact Measurement System for the Range of Motion of the Hand

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the h...

متن کامل

A novel pin distraction device for arthroscopic assessment of the medial meniscus in dogs.

OBJECTIVE To describe an extra-articular joint distractor for meniscal examination and treatment during canine stifle arthroscopy. STUDY DESIGN Case series. ANIMALS Dogs >or=20 kg with suspected cranial cruciate ligament (CrCL) deficiency. METHODS A custom designed linear side bar was constructed to allow invasive pin distraction of the stifle joint. Its design efficacy for distraction of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of veterinary research

دوره 77 7  شماره 

صفحات  -

تاریخ انتشار 2016