Comparison between power line communication multipath model and coaxial cable interferometer theory
نویسندگان
چکیده
The authors have studied a new method to find parameters of broadband power line communication channel model. Lossless power line communication channel model is compared with classical interferometers approach to develop this model. The authors also used coaxial cables to simulate a multipath channel, because it can behave like a lossless power line communication channel. Thus, measurements were carried out with a network analyzer to find S parameters. The modeling parameters, for the multipath model were found after using MATLAB software and classical interferometers approach. Then, theoretical and experimental results are presented and compared. Copyright © 2012 John Wiley & Sons, Ltd.
منابع مشابه
Comparison of different Channel Modeling Techniques used in the BPLC Systems
The paper compares different channel models used for modeling Broadband Power-Line Communication (BPLC) system. The models compared are Zimmermann and Dostert, Philipps, Anatory et al and Anatory et al generalized Transmission Line (TL) model. The validity of each model was compared in time domain with ATP-EMTP software which uses transmission line approach. It is found that for a power-line ne...
متن کاملPassive Sensing Node Network for Monitoring Performance of RF Connector-Coaxial Cable System
A passive sensing node technology is introduced for monitoring the integrity of RF coaxial transmission lines and associated RF connectors in the UHF range of frequencies. Each passive sensing node is powered by a transmission line coupler inside the coaxial cable. Passive sensing node sensing elements, fineline interconnect metallurgy, transmission line coupler, and electronics are packaged on...
متن کاملA Coaxial Cable Fabry-Perot Interferometer for Sensing Applications
This paper reports a novel coaxial cable Fabry-Perot interferometer for sensing applications. The sensor is fabricated by drilling two holes half-way into a coaxial cable. The device physics was described. The temperature and strain responses of the sensor were tested. The measurement error was calculated and analyzed.
متن کاملHigh Voltage Pulse Generator by connecting Normal Coaxial Cable in series and in parallel without using Blumlein method
In order to carry out the simulation of the electrical noise, a pulse generator with fast rise time is needed. For this reason, the pulse generator using a coaxial cable is usually used. The pulse generator consists of a DC power supply, a charging resistor, a coaxial cable, a relay, and a terminator. Even the same voltage as charge voltage was outputted when the termination of the impedance wa...
متن کاملHigh Voltage Pulse Generator by connecting Normal Coaxial Cables in series and in parallel without using Blumlein method
In order to carry out the simulation of the electrical noise, a pulse generator with fast rise time is needed. For this reason, the pulse generator using a coaxial cable is usually used. The pulse generator consists of a DC power supply, a charging resistor, a coaxial cable, a relay, and a terminator. Even the same voltage as charge voltage was outputted when the termination of the impedance wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Int. J. Communication Systems
دوره 27 شماره
صفحات -
تاریخ انتشار 2014