Transverse Strength of Reinforced Denture Base Resin with Metal Wire and E-Glass Fibers

نویسنده

  • M. Vojdani
چکیده

Statement of problem: Fracture strength of a denture base resin is of great concern, and many approaches have been used to strengthen acrylic resin dentures. Purpose: The aim of this study was to measure the transverse strength of a heat polymerized acrylic resin, after reinforcement with metal wire and two types of glass fibers. Materials and Methods: Forty rectangular specimens (65.0×10.0×3.3 mm) of a heatcured acrylic resin were made according to ISO/FDI 1567. Group I (control group) consisted of 10 specimens with no reinforcement. Specimens in group II reinforced with sandblasted metal wires. Group III and IV strengthened with woven (Stick Net) and continuous unidirectional (Stick) fibers respectively. The specimens were polymerized according to manufacturer’s recommendation. The transverse strengths were assessed with a 3point bending test at cross head speed of 5mm/min. One-way ANOVA was carried out to compare and detect any differences among groups (α=0.05). Results: Mean transverse strength (SD) of unreinforced specimens was 85.44 (8.6) MPa. The transverse strength increased significantly to 97.97 (5.5) MPa, 109.69 (5.8) MPa, and 127.13 (6.4) MPa in Metal wires, Stick Net, and stick fibers groups, respectively. Conclusion: The transverse strength of heat-polymerized denture base resin was enhanced considerably by using metal wire and glass fibers reinforcements. However, the addition of unidirectional glass fibers was significantly more effective method to improve flexural strength of denture base acrylic resin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Evaluation of Effect of Reinforced Autopolymerizing Resin on the Flexural Strength of Repaired Heat-polymerized Denture Base Resin before and after Thermocycling

Aims and Objective Denture fractures are a common problem in clinical practice. Despite the use of different reinforcement materials (metal wires, metal plates, and various types of fibers) for denture repairs, recurrent fractures are still common. The purpose of this study was to compare the maximum flexural loads of the heat-polymerized denture base resin when repaired with autopolymerizing r...

متن کامل

The Reinforcement Effect of Nano-Zirconia on the Transverse Strength of Repaired Acrylic Denture Base

Objective. The aim of this study was to evaluate the effect of incorporation of glass fiber, zirconia, and nano-zirconia on the transverse strength of repaired denture base. Materials and Methods. Eighty specimens of heat polymerized acrylic resin were prepared and randomly divided into eight groups (n = 10): one intact group (control) and seven repaired groups. One group was repaired with auto...

متن کامل

Flexural strength of heat-polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers.

STATEMENT OF PROBLEM Despite the favorable properties of conventional PMMA used as a denture base material, its fracture resistance could be improved. PURPOSE This in vitro study was performed to determine whether the flexural strength of a commercially available, heat-polymerized acrylic denture base material could be improved through reinforcement with 3 types of fibers. MATERIAL AND METH...

متن کامل

Reinforcing effect of glass fiber-reinforced composite reinforcement on flexural strength at proportional limit of a repaired denture base resin

Objective: This study evaluated the reinforcing effect of glass fiber-reinforced composite (FRC) reinforcement on flexural strength at the proportional limit (FS-PL) of a repaired denture base resin. Materials and methods: Repaired denture base resins reinforced with metal and with FRC reinforcement, and that without reinforcement were tested. The ultimate flexural strength, the FS-PL and the e...

متن کامل

Transverse Strength of Repaired Denture Base Material with Wire and Two Auto Polymerized Acrylic Resin

Received: 15 October 2006 Accepted: 16 May 2007 Abstract: Objective: The purpose of this study was to evaluate the transverse strength of one brand of denture base material repaired with two autopolymerized acrylic resins with and without wire reinforcement. Materials and Methods: Eighty samples (2.5×10×65 mm) were fabricated and divided into five groups. The control group was left intact. Grou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007