Preliminary investigation of a multiple-image radiography method

نویسندگان

  • Miles N. Wernick
  • Oliver Wirjadi
  • Dean Chapman
  • Oral Oltulu
  • Zhong Zhong
  • Yongyi Yang
چکیده

Conventional radiography seeks to produce, at each location in the image plane, a measure of the x-ray absorption of the object. In this paper, we present a method of determining a much more complete object description at each point, namely the intensity distribution (as a function of angle) of the emerging x-ray beam. From this distribution one can compute many different images, depicting the refraction, absorption, and scattering characteristics of the object. The method is based on acquisition of multiple x-ray images using monochromator and analyzer crystals, followed by a deconvolution operation (over angle) at each pixel. Parameters of the deconvolved angular intensity function are measured to obtain the various images of interest. We present experimental results obtained using x-rays produced by a synchrotron, along with simulated images showing the effect of noise in a hypothetical photonlimited imaging situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiple-image radiography for human soft tissue.

Conventional radiography only provides a measure of the X-ray attenuation caused by an object; thus, it is insensitive to other inherent informative effects, such as refraction. Furthermore, conventional radiographs are degraded by X-ray scatter that can obscure important details of the object being imaged. The novel X-ray technology diffraction-enhanced imaging (DEI) has recently allowed the v...

متن کامل

Image quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study

Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...

متن کامل

Implementation of neutron radiography in the MNSR Low Power Research Reactor

Neutron radiography is an unique, advanced and useful non-destructive test method in various industries and researches. Nuclear reactors are powerful and stable neutron sources for the neutron radiography system. In this research, the MNSR research reactor has been used as a neutron source for a neutron radiography system, and its neutron beam parameters have been evaluated. Also, using the dir...

متن کامل

Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites

The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002