Cardiac resynchronization improves coronary blood flow.

نویسندگان

  • Aydin Yildirim
  • Ozer Soylu
  • Bahadir Dagdeviren
  • Mehmet Ergelen
  • Seden Celik
  • Ertugrul Zencirci
  • Tuna Tezel
چکیده

Asynchronous ventricular activation, induced by left bundle branch block, is known to have deleterious effects on the systolic and diastolic functions of the left ventricle (LV). Cardiac resynchronization therapy (CRT) has been proposed as a complementary method to improve the LV systolic performance by restoring the synchronized contraction patterns in patients with advanced heart failure and left bundle branch block. However, the effect of CRT on myocardial blood flow is not well established. In the present study, we therefore examined the coronary blood flow in 20 patients with idiopathic dilated cardiomyopathy, implanted with a biventricular pacemaker according to the established CRT criteria. Color Doppler settings were adjusted for the optimal coronary flow imaging, and coronary flow velocities were obtained in all patients. Typical diastolic predominant phasic Doppler spectrum of the distal left anterior descending coronary artery (LAD) was recorded. Conventional echocardiographic variables, peak values of the diastolic and systolic LAD velocities, and the velocity time integrals were measured for three or five consecutive beats during CRT with pacemaker on and off. Successful CRT with biventricular pacing increased coronary blood flow velocities of the distal LAD in addition to its well-known benefits on the systolic and diastolic LV performance in patients with significant dyssynchrony. CRT decreased duration of mitral regurgitation and increased diastolic filling time. Peak diastolic velocities and velocity time integral of the distal LAD were increased significantly. In conclusion, successful CRT with biventricular pacing improves coronary blood flow velocities of the distal LAD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Nitric Oxide and Prostaglandins in the Effect of Adenosine on Contractility, Heart Rate and Coronary Blood Flow in Guinea Pig Isolated Heart

It is a well-established fact that adenosine and its receptor subtypes (A 1 and A ) are involved in changes of contractility, heart rate and coronary blood flow (CBF) under different circumstances. This study was conducted to evaluate the role of nitric oxide and prostaglandins in development of these changes. For this purpose, Nitro-L-Arginine methyl ester (L-NAME), and indomethacin as inhibit...

متن کامل

Characterization of coronary vein motion in patients with low and moderate ejection fractions

Background Three-dimensional, whole-heart, navigator-gated, contrast-enhanced MRI techniques are used to acquire cMRVs which can be used for planning lead placement in cardiac resynchronization therapy (CRT). In order to reduce cardiac motion artifacts, it is desirable to set the trigger delay time to acquire image data only during periods of low vessel motion, typically assumed to be during di...

متن کامل

The effect of eight weeks of cardiac rehabilitation on hemodynamic parameters and blood lipid profile in male patients 55-70 years old CABG coronary artery bypass graft surgery

Extended Abstract 1.Introduction According to the World Health Organization (2010), cardiovascular disease (CHD) is the most common cause of death worldwide (1). Sadeghpour et al. (2010) have shown that one of the most common problems after coronary artery bypass grafting is extensive hemodynamic changes. Incomplete drainage of blood and blood fluid from the pericardium and pleura reduces hea...

متن کامل

Cardiac Resynchronization Therapy Using a Dual Chamber Pacemaker in Patients with Severe Left Ventricular Dysfunction and a Left Bundle Branch Block

Through the use of a dual chamber (DDD) pacemaker, we achieved a cardiac resynchronization effect in a 51-year-old female patient who was transferred to our hospital from another hospital for an operation for three-vessel coronary artery disease. Her electrocardiogram showed a left bundle branch block (LBBB) and a prolonged QRS interval of 166 milliseconds. Severe left ventricle (LV) dysfunctio...

متن کامل

Maximal electric separation-guided placement of right ventricular lead improves responders in cardiac resynchronization defibrillator therapy.

BACKGROUND Cardiac resynchronization therapy is widely used for the treatment of heart failure. Recent data suggest that electric separation during left ventricular pacing varies within the right ventricle (RV). We hypothesized that placement of the RV lead guided by maximal electric separation (MES) would improve response to cardiac resynchronization therapy compared with standard apical place...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Tohoku journal of experimental medicine

دوره 211 1  شماره 

صفحات  -

تاریخ انتشار 2007