Role of laser pre-pulse wavelength and inter-pulse delay on signal enhancement in collinear double-pulse laser-induced breakdown spectroscopy

نویسندگان

  • P. K. Diwakar
  • A. Hassanein
چکیده

a r t i c l e i n f o Keywords: LIBS Double pulse LIBS Plasma diagnostics LPP Dual-pulse (DP) laser-induced breakdown spectroscopy (LIBS) provides significant improvement in signal intensity as compared to conventional single-pulse LIBS. We investigated collinear DPLIBS experimental performance using various laser wavelength combinations employing 1064 nm, 532 nm, and 266 nm Nd:YAG lasers. In particular, the role of the pre-pulse laser wavelength, inter-pulse delay times, and energies of the reheating pulses on LIBS sensitivity improvements is studied. Wavelengths of 1064 nm, 532 nm, and 266 nm pulses were used for generating pre-pulse plasma while 1064 nm pulse was used for reheating the pre-formed plasma generated by the pre-pulse. Significant emission intensity enhancement is noticed for all reheated plasma regardless of the pre-pulse excitation beam wavelength compared to single pulse LIBS. A dual peak in signal enhancement was observed for different inter-pulse delays, especially for 1064:1064 nm combinations, which is explained based on temperature measurement and shockwave expansion phenomenon. Our results also show that 266 nm:1064 nm combination provided maximum absolute signal intensity as compared to 1064 nm:1064 nm or 532 nm:1064 nm. Laser-induced breakdown spectroscopy (LIBS) technique is useful for a variety of applications including elemental analysis, detecting airborne biological agents, quantitative analysis of aerosols etc. [1–3]. Although LIBS is suited for various applications, this technique possesses lower sensitivity and precision than the other forms of elemental analysis. Improvements in the sensitivity of LIBS can be achieved by enhancing the signal strength or reducing the background noise. Recent advancements with femtosecond (fs) laser based LIBS and polarization resolved LIBS showed sharp reduction in background continuum noise, but the technology of a handheld fs laser system is still far away [2,4,5]. Among the various methods proposed for improving the detection sensitivity of LIBS, double-pulse (DP) excitation is more promising [6–11]. The term " double-pulse " can be defined as follows; two laser pulses used for LIBS excitation, which are separated in time by a period of few nanoseconds to several microseconds. Quite recently, several research groups explored applications for DP because of advances in laser technology and better analytical detection systems [3,6,9,11–15]. Double pulses have been found to increase LIBS sensitivity for the analysis of liquids [16], solids immersed in liquid [17], and solids [18,19]. Apart from analytical applications , DP technique has been used in laser-produced plasma (LPP) for x-ray [20,21] and EUV emission enhancement …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double pulse laser ablation and plasma: Laser induced breakdown spectroscopy signal enhancement

A review of recent results of the studies of double laser pulse plasma and ablation for laser induced breakdown spectroscopy applications is presented. The double pulse laser induced breakdown spectroscopy configuration was suggested with the aim of overcoming the sensitivity shortcomings of the conventional single pulse laser induced breakdown spectroscopy technique. Several configurations hav...

متن کامل

Double-pulse Nd:YAG-CO2 LIBS Excitation for Bulk and Trace Analytes

Laser-induced breakdown spectroscopy [LIBS] is a commonly used technique for multi-element analyses for various applications such as space exploration, nuclear forensics, environmental analysis, process monitoring. The advantages of the LIBS technique include robustness, ease of use, field portability, and real-time, non-invasive multi-element analyses. However, in comparison to other lab based...

متن کامل

Electron-ion relaxation time dependent signal enhancement in ultrafast double-pulse laser-induced breakdown spectroscopy

We investigated the emission properties of collinear double-pulse compared to single-pulse ultrafast laser induced breakdown spectroscopy. Our results showed that the significant signal enhancement noticed in the double pulse scheme is strongly correlated to the characteristic electron-ion relaxation time and hence to the inter-pulse delays. Spectroscopic excitation temperature analysis showed ...

متن کامل

Thermodynamic and spectroscopic properties of Nd:YAG–CO2 Double-Pulse Laser-Induced Iron Plasmas

a r t i c l e i n f o Keywords: Laser-induced breakdown spectroscopy Double pulse LIBS Laser ablation Laser heating Laser-induced particles Double-Pulse Laser-Induced Breakdown Spectroscopy of iron using both Nd:YAG and TEA–CO 2 lasers has been investigated to better understand mechanisms of signal enhancement. The signal dependence on the delay between the two laser pulses shows an enhanced si...

متن کامل

The importance of longer wavelength reheating in dual-pulse laser-induced breakdown spectroscopy

Dual-pulse laser-induced breakdown spectroscopy (LIBS) provides improved sensitivity compared to conventional single-pulse LIBS. We used a combination of Nd: yttrium aluminum garnet (YAG) and CO2 lasers to improve the sensitivity of LIBS. Significant emission intensity enhancement is noticed for both excited neutral lines and ionic lines for dual-pulse LIBS compared to single-pulse LIBS. Howeve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013