Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities

نویسندگان

  • Qadreyah A. Al-Matawah
  • Sameer F. Al-Zenki
  • Jafer A. Qasem
  • Tahani E. Al-Waalan
  • Ahmed H. Ben Heji
چکیده

The prevalence of Legionella pneumophilia in water systems of residential facilities in Kuwait was performed during the period from November 2007 to November 2011. A total of 204 water samples collected from faucets and showerheads in bathrooms (n = 82), taps in kitchens (n = 51), and water tanks (n = 71), from different locations of residential facilities in Kuwait were screened for Legionella pneumophila by the standard culture method and by real time polymerase chain reaction (RT-PCR). Out of the 204 samples, 89 (43.6%) samples were positive for Legionella spp., 48 (23.5%) samples were detected by the standard culture method, and 85 (41.7%) were detected by RT-PCR. Of the culture positive Legionella samples, counts ranged between 10 to 2250 CFU/L. Serological typing of 48 Legionella isolates revealed that 6 (12.5%) of these isolates belonged to Legionella pneumophila serogroup 1, 37 (77.1%) isolates to Legionella pneumophila serogroup 3, and 1 isolate each (2.1%) belonged to serogroups 4, 7, and 10. The minimum inhibitory concentration (MICs) of the 46 environmental L. pneumophila isolates against the 10 antimicrobials commonly used for Legionella infection treatments were determined. Rifampicin was found to be the most active against L. pneumophila serogroups isolates in vitro.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Legionella in clinical specimens and hospital water supply facilities: molecular detection and genotyping of the isolates.

OBJECTIVE To evaluate genus- and species-specific polymerase chain reactions (PCRs) for the detection of the genus Legionella and the species Legionella pneumophila in clinical specimens and hospital water supplies, and to establish a simple and reproducible random amplification of polymorphic DNA (RAPD)-PCR technique for genotyping of Legionella. MATERIALS AND METHODS A total of 70 respirato...

متن کامل

Isolation and identification of Legionella spp. from different aquatic sources in south-west of Iran by molecular &culture methods

Legionella pneumophila, the causative agent of Legionnaires’ diseases (LD) is usually transmitted to humans via inhalation of aerosols from contaminated natural and manmade water sources. These organisms may become fatal especially in immunocompromised patients and LD is the one of the important disease from a public health perspective. This survey investigated the frequency of Legionella spp. ...

متن کامل

Legionella pneumophila in residential water supplies: environmental surveillance with clinical assessment for Legionnaires' disease.

Although cases of community-acquired Legionnaires' disease have been epidemiologically linked to residential water supplies, the risk of acquiring Legionnaires' disease from exposure to Legionella pneumophila in residential water systems is uncertain. The residential water supplies of 218 members of the American Legion in six different geographical areas in Pittsburgh were cultured for L. pneum...

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012