Biomechanical response of the human clavicle: the effects of loading direction on bending properties.

نویسندگان

  • Andrew R Kemper
  • Joel D Stitzel
  • Craig McNally
  • H Clay Gabler
  • Stefan M Duma
چکیده

The purpose of this study was to determine the influence of loading direction on the structural response of the human clavicle subjected to three-point bending. A total of 20 clavicles were obtained from 10 unembalmed fresh-frozen postmortem human subjects ranging from 45 to 92 years of age. The right and left clavicles from each subject were randomly divided into two test groups. One group was impacted at 0 degrees from the transverse plane, and the second group was impacted at 45 degrees angle from the transverse plane. There was no statistically significant difference in peak force (p = .22), peak moment (p = .30), or peak displacement (p = .44) between specimens impacted at 0 degrees versus 45 degrees from the transverse plane. However, there was a significant difference in the structural stiffness (p = .01) and peak strain (p < .01) between specimens impacted at 0 degrees versus 45 degrees from the transverse plane. The peak strain, however, must be evaluated with caution because of the variation in fracture location relative to the strain gauge. Due to the controlled matched data set, the differences in the structural stiffness with respect to loading direction can be attributed to the complex geometry of the clavicle and not material differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft ...

متن کامل

Biomechanical analysis of blast-induced traumatic brain injury

  Purpose: Blast-induced traumatic brain injury (bTBI) is one of the causes of death or permanent   invalidity which can occur unexpectedly in both military and civilian populations. This study   set out to conduct a combined Eulerian-Lagrangian computational analysis of the interaction   between a single planar blast wave and a human head in order to assess the extent of intracranial   shock w...

متن کامل

Evaluation of Fatigue Properties of Asphalt Mixtures Containing Reclaimed Asphalt using Response Surface Method

This paper presents the effects of different amounts of reclaimed asphalt on fatigue life of asphalt mixtures. Central composite method was used to design of experiments based on response surface method (RSM). Binder type (Pen 60/70 and Pen 85/100), reclaimed asphalt pavement (RAP) content (25, 50 and 75%) and loading strain (150, 250 and 350 micro strain) were selected as independent variables...

متن کامل

Non-linear Thermo-mechanical Bending Behavior of Thin and Moderately Thick Functionally Graded Sector Plates Using Dynamic Relaxation Method

In this study, nonlinear bending of solid and annular functionally graded (FG) sector plates subjected to transverse mechanical loading and thermal gradient along the thickness direction is investigated. Material properties are varied continuously along the plate thickness according to power-law distribution of the volume fraction of the constituents. According to von-Karman relation for large ...

متن کامل

Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied biomechanics

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2009