Simulation of the Cross-Coupling among Snap Back Devices under Transient High Current Stress

نویسندگان

  • G. Groos
  • N. Jensen
  • M. Denison
  • M. Stecher
چکیده

A main issue for on-chip protection of Smart Power ICs against ESD and other transient high current pulses is the cross-coupling between the protection device (PD) and the device to be protected. In many cases both are npn transistors (e.g. parasitic of DMOS), therefore we investigate the coupled triggering of such devices by numerical device simulations. We show that even considering the separate transient trigger voltages Vtr does not guarantee protective action. Under certain conditions, even though the PD shows a lower Vtr than the circuit and it conducts the current in the beginning of the pulse, the circuit device takes over the stress current, possibly being destroyed. This explains observations of low ESD robustness and enables design measures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gate recess engineering of pseudomorphic In/sub 0.30/GaAs/GaAs HEMTs - Electronics Letters

and a 15011s time constant. These pulses are applied on the collector of the simulated devices, while their emitter and substrate are grounded. The thermal boundary condition is considered to be a constant temperature of 300K at the bottom of the simulation domain which corresponds to the substrate electrode. Fig. 2 shows the calculated transient voltage responses of the two transistors submitt...

متن کامل

Salt stress and transplant time in snap bean: growth and productive behaviour

High quality water is less available for agriculture and thus farmers often use saline water, that affects crop growth and yield. Snap bean (Phaseolus vulgaris) is sensitive to soil and water salinity, and also to heat stress. The aim of this research is to evaluate if a postponed transplant (high temperature stress) of snap bean can influence growth and yield under saline conditions. Snap bean...

متن کامل

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

Cross Entropy-Based High-Impedance Fault Detection Algorithm for Distribution Networks

The low fault current of high-impedance faults (HIFs) is one of the main challenges for the protection of distribution networks. The inability of conventional overcurrent relays in detecting these faults results in electric arc continuity that it causes the fire hazard and electric shock and poses a serious threat to human life and network equipment. This paper presents ​an HIF detection algori...

متن کامل

Improvement of Transient Voltage Profile Using Power Control of the DFIG-Based Wind Farm Under Severe Voltage Dip Event

Improving transient voltage stability is one of the most important issues that must be provided by doubly fed induction generator (DFIG)-based wind farms (WFs) according to the grid code requirement. This paper proposes adjusted DC-link chopper based passive voltage compensator and modified transient voltage controller (MTVC) based active voltage compensator for improving transient voltage stab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004