Novel ibuprofen potentiometric membrane sensors based on tetraphenylporphyrinato indium(III).

نویسندگان

  • Saad S M Hassan
  • Wagiha H Mahmoud
  • Mohamed A F Elmosallamy
  • Mahra H Almarzooqi
چکیده

Two novel potentiometric membrane sensors responsive to the ibuprofen drug have been developed. These incorporate poly(vinyl chloride) and polyurethane matrix membranes containing 5,10,15,20-tetraphenylporphrinato (TPP) indium(II) ionophore plasticized with dibutylsebacate. The sensors show a near-Nernstian response with anionic slopes of -53 and -55 mV decade(-1), over the concentration range of 4.2 x 10(-6)-1.0 x 10(-2) and 3.3 x 10(-6)-1.0 x 10(-2) M ibuprofen within pH ranges of 4-9 and 5-9 for PVC and PU matrix membranes, respectively. A sensor based on a polyurethane membrane displays a lower detection limit and a wider linear working range, and a sensor based on a PVC membrane exhibits a better overall selectivity, especially in the presence of lipophilic organic anions. Both sensors are used for the quantification and quality-control assessment of ibuprofen in pharmaceutical preparations. The average recoveries are 99.1+/-0.3% and 99.3+/-0.3% for TPP In(III)-PVC and TPP In(III)-PU based membrane sensors, respectively. High selectivities towards ibuprofen in the presence of many anions, drug excipients and diluents are offered by both sensors, which exhibit a non-Hofmeister selectivity pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Chromium(III) and Magnesium(II) Ions in Pharmacological and Real Water Samples using Potentiometric Sensors based on Chitosan Schiff base Derivative as Green and Sensitive Ionophore

In the study, novel and sensitive carbon paste electrodes (CPEs) developed for thepotentiometric measurement of Cr(III) and Mg(II) ions in pharmacological and water samples.CPEs as indicator electrodes were prepared from a mixture of four components, includinggraphite powder, paraffin oil, multi-walled carbon nanotubes (MWCNTs), and a greenionophore (Chitosan Schiff base...

متن کامل

Chloride-selective membrane electrodes and optodes based on an indium(III) porphyrin for the determination of chloride in a sequential injection analysis system.

Two quasi-independent methods for potentiometric and optical determination of chloride were simultaneously implemented in a flow system, providing real-time assessment of the quality of results. A potentiometric and an optical polymeric membrane doped with the same indium(III) octaethyl-porphyrin were used as sensor ionophore. The working mechanism and the analytical characteristics of these po...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2003