Assay of CCNU in tumor by RP-HPLC.
نویسندگان
چکیده
This paper reports a RP-HPLC method for the determination of Lomustine (CCNU) in mouse tumor tissue. CCNU was separated and determined on a reverse-phase C18 5 microm column with a mobile phase of H2O-acetonitrile (54:46), detected at 254 nm and no internal standard. The calibration curve was linear (r = 0.9999) within the range of 0.98-15.68 microg/ml for CCNU. The recovery ratio of CCNU was 68.64% (n = 5). The relative standard deviation (RSD) was 0.32%. This method is simple and accurate.
منابع مشابه
Simultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form
The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...
متن کاملQuantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملQuantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Artificial cells, blood substitutes, and immobilization biotechnology
دوره 33 3 شماره
صفحات -
تاریخ انتشار 2005