Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts.

نویسندگان

  • Dean C-S Tai
  • Bryan J Caldwell
  • Ian J LeGrice
  • Darren A Hooks
  • Andrew J Pullan
  • Bruce H Smaill
چکیده

Fast voltage-sensitive dyes are widely used to image cardiac electrical activity. Typically, the emission spectrum of these fluorochromes is wavelength shifted with altered membrane potential, but the optical signals obtained also decay with time and are affected by contraction. Ratiometry reduces, but may not fully remove, these artifacts. An alternate approach has been developed in which the time decay in simultaneously acquired short- and long-wavelength signals is characterized nonparametrically and removed. Motion artifact is then identified as the time-varying signal component common to both decay-corrected signals and subtracted. Performance of this subtraction technique was compared with ratiometry for intramural optical signals acquired with a fiber-optic probe in an isolated, Langendorff-perfused pig heart preparation (n = 4) stained with di-4-ANEPPS. Perfusate concentration of 2,3-butanedione monoxime was adjusted (7.5-12.5 mM) to alter contractile activity. Short-wavelength (520-600 nm) and long-wavelength (>600 nm) signals were recorded over 8-16 cardiac cycles at 6 sites across the left ventricular free wall in sinus rhythm and during pacing. A total of 451 such data sets were acquired. Appreciable wall motion was observed in 225 cases, with motion artifact classed as moderate (less than modulation due to action potential) in 187 and substantial (more than modulation due to action potential) in 38. In all cases, subtraction performed as well as, or better than, ratiometry in removing motion artifact and decay. Action potential morphology was recovered more faithfully by subtraction than by ratiometry in 58 of 187 and 31 of 38 cases with moderate and substantial motion artifact, respectively. This novel subtraction approach may therefore provide a means of reducing the concentration of uncoupling agents used in cardiac optical mapping studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ratiometry of transmembrane voltage-sensitive fluorescent dye emission in hearts.

Transmembrane voltage-sensitive fluorescence measurements are limited by baseline drift that can obscure changes in resting membrane potential and by motion artifacts that can obscure repolarization. Voltage-dependent shift of emission wavelengths may allow reduction of drift and motion artifacts by emission ratiometry. We have tested this for action potentials and potassium-induced changes in ...

متن کامل

Motion artefact in voltage-sensitive fluorescent dye emission during repeated ischemia of isolated heart.

Motion artefact (MA) in voltage-sensitive fluorescent signals causes significant debasement of action potential. During ischemia and reperfusion in isolated rabbit heart, this artefact develops in a manner which may be described by the time of its onset, level, and shape. The MA during ischemia: (a) may become substantial with approximately two minutes delay after establishing global ischemia; ...

متن کامل

Voltage-sensitive dye mapping in Langendorff-perfused rat hearts.

An imaging system suitable for recordings from Langendorff-perfused rat hearts using the voltage-sensitive dye 4-[beta-[2-(di-n-butylamino)-6-naphthyl]vinyl]pyridinium (di-4-ANEPPS) has been developed. Conduction velocity was measured under hyper- and hypokalemic conditions, as well as at physiological and reduced temperature. Elevation of extracellular [K(+)] to 9 mM from 5.9 mM caused a slowi...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 287 3  شماره 

صفحات  -

تاریخ انتشار 2004