SIS18 will serve as booster synchrotron for the proposed International Accelerator Facility FAIR [1] at GSI. The aim is to provide high intensity proton and low charge state heavy ion beams of e.g. U 28+ -ions with a repetition rate of 2.7 – 4 cycles per second. The operation with low charge state heavy ion beams requires modifications of the injection system. At present, the maximum field strength of the electrostatic septum is not sufficient for injection of U 28+ -beams at the standard energy of 11.4 MeV/u. Furthermore, by means of an increased acceptance, beam loss in the injection channel and corresponding desorption gas production shall be minimized. THE SIS18 INJECTION SYSTEM The injection system at the end of the transfer channel consists of an inflector magnet and an electrostatic septum. Both devices and their supply units will be replaced forming a new system as shown in figure 1 [2]. Figure 1: New injection system with curved inflector magnet and 300 kV electrostatic septum. DESIGN AND IMPROVMENTS OF THE

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Intensity Uranium Operation in Sis18

In order to follow the requirements of the ongoing experimental program at GSI and later on of the planned operation as a booster for the Facility for Antiproton and Ion Research FAIR, the intensity of uranium beams in SIS18 must be enhanced significantly. The goals are to increase the number of particles per cycle up to the space charge limit and to enhance the average intensity by an increase...

متن کامل

Acceleration of U-beams in the SIS18

Introduction To prepare the acceleration of highest intensities of intermediate charge state heavy ion beams for the FAIR project, several technical projects have been summarized in the SIS18 upgrade program. The various technical measures of this program are continuously accompanied and verified by machine experiments. Major goal is the reduction of ionization beam loss. The strong dependence ...

متن کامل

SIS18 – Intensity Record with Intermediate Charge State Heavy Ions

A new development direction towards ultimate heavy ion beam intensities is being pursued at GSI for FAIR. So far, most of the heavy ion synchrotrons have been operated with high charge state heavy ions. In order to reach intensities of more than 10/U-ions per cycle [1, 2], SIS18 and SIS100 must be operated with intermediate charge state ions [3, 4]. Such a high intensity operation with intermed...

متن کامل

A new Signal Treatment for SIS18 Beam Position Monitors

Within the FAIR SIS18 upgrade the data acquisition hardware as well as the concept for signal treatment of the Beam Position Monitoring system (BPM) were renovated. The former BPM system was based on the analog narrowband signal processing (see [1]). Since any information concerning an individual bunch is lost, observation in the turn-by-turn scale as well as tune measurement is impossible. Hen...

متن کامل

Experimental Investigation of Resonance Induced effects in SIS18

The upgrade of the SIS18 to become the injector of the SIS100 requires beam loss control/limitation at the percent level [1]. The storage of high intensity beams needs careful choice of the working point and of compensation of the resonances crossing the beam space charge tune spread (as large as ∆Q ∼ 0.5). However, the linear coupling may be useful for balancing beam emittances and improving m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008