An on-line solid phase extraction procedure for the routine quantification of urinary methylmalonic acid by liquid chromatography-tandem mass spectrometry.

نویسندگان

  • Fabian Kirchhoff
  • Stephan Lorenzl
  • Michael Vogeser
چکیده

BACKGROUND The goal of this study was to develop and to validate an improved isotope-dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of methylmalonic acid (MMA) in urine. METHODS A previously described sample preparation protocol requires two solvent extraction steps, including evaporation. The first extraction is to extract the analyte from the sample, and second occurs following derivatization of the extract. In the method described here, the second evaporation step was substituted by on-line solid phase extraction employing column-switching and a permanent co-polymer based extraction cartridge. A standard validation protocol was applied to investigate the performance of the method. RESULTS The method was found to be linear in the clinically relevant range of concentrations (6-100 μmol/L). Total coefficients of variation were below 10% and inaccuracy was <10% for quality control samples at three concentrations. CONCLUSIONS By omitting one evaporation step, the semi-automated method described in this article enables for more convenient work-flow in the quantification of urinary MMA compared to the previous protocol. This is of relevance for MMA measurement in the routine clinical laboratory setting. Validation demonstrated acceptable analytical performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

An on-line solid phase extraction procedure for the routine quantification of caspofungin by liquid chromatography-tandem mass spectrometry.

BACKGROUND Extensive sets of data are required to investigate the potential use of a therapeutic drug monitoring with individualization of dosage of the antimycotic compound caspofungin. The goal was to develop an improved liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for this aim. METHODS Following protein precipitation, on-line solid phase extraction was performed for sam...

متن کامل

Quantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction.

Quantification of the new immunosuppressant sirolimus (syn. rapamycin; Rapamune) in whole blood by chromatography is essential for its clinical use since no immunoassay is available although monitoring is mandatory. Here we report on a rapid and convenient liquid chromatography (LC-tandem mass spectrometry method and describe our practical experience with its routine use. Whole blood samples we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 48 11  شماره 

صفحات  -

تاریخ انتشار 2010