Influence of Image Processing Conditions of Debye Scherrer Ring Images in X-ray Stress Measurement Using an Imaging Plate

نویسندگان

  • Toshihiko SASAKI
  • Yukio HIROSE
  • Katsunari SASAKI
چکیده

ABSTXACT This paper describes the study of the possibility of x-ray stress measurement in which stresses are obtained by analyzing the whole of one diffraction ring detected with a two-dimensional x-ray detector called an imaging plate (IP). The theory of the stress determination proposed by Taira et al (1978) was shown and advanced to make measurable all plane stress components. The experiment showed good agreement with stresses applied mechanically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An image plate chamber for x-ray diffraction experiments in Debye–Scherrer geometry

A new design for implementation of x-ray diffraction experiments is proposed. The exploitation of the imaging plate technique opens new possibilities to carry out diffraction experiments. The detector chamber in Debye–Scherrer geometry equipped with an image plate takes advantage of this technology such as high resolution, high sensitivity, linearity in intensity, and linearity over the detecto...

متن کامل

Development of Measuring System for Stress by Means of Image Plate for Laboratory X-ray Experiment

A single exposure X-ray incidence method for determining stress using the whole part of the Debye-Scherrer ring was studied. An image plate (IP) was used in this study as an area detector. A stress measuring system using an X-ray two-dimensional detector was developed. This was designed in order to be used in the authors’ X-ray laboratory. The background and the purpose of this study is to poin...

متن کامل

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

متن کامل

Study of the Fatigue Fracture Surface Regions of Steels Using Microbeam Synchrotron X-Ray Diffraction

A cyclic plastic zone area near fatigue-fractured surface was studied using a back-reflection camera and high intensity, microbeam, synchrotron X-ray source (SR) in order to measure the variation of the stress intensity factor range (AK) along the fatigue fracture. The existence of subgrains within the cyclic plastic region was shown by the appearance of small spots in the Debye-Scgerrer rings ...

متن کامل

Evaluation of the effect of four current Iranian processing solutions on the image quality of two dental X-ray films

Evaluation of the effect of four current Iranian processing solutions on the image quality of two dental X-ray films Dr. M. Imani Moghadam* - Dr. AHA. Afzali** - Eng. S. Ebrahim Zadeh*** *- Assistant Professor of Dentomaxillofacial Radiology Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Radiologist. ***- The member of Mashhad University of Medical Sciences. Backgrou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998