Comparison of four different algorithms for the calculation of radioimmunoassay standard curves.

نویسندگان

  • I Marschner
  • R Herndl
  • P C Scriba
چکیده

Standard curves from 150 determinations of 10 different hormone radioimmunoassays have been evaluated using the following four procedures: logit transformation as performed by Rodbard, Healy's 4-component-logit, spline approximation and a linear interpolation program. The results, calculated by computer, have been compared with manual analysis as the refernce method. The influece of various correction factors has been studied by artificial insertion of outliers. Approximately two thirds of all investigated curves could be calculated with almost equal success using all 4 methods. In calculating the remaining third of the standard curves, each method showed characteristic errors which depended upon the reliability of the assay data and the kind of outliers. The results suggest that the smoothing by spine function is the most flexible method in approximating a radioimmunoassay standard curve. In comparison with the other methods it is less influenced by random errors and fits the characteristic and symmetry of the ideal curve most exactly. The 4-component logit which has been extended by data screening is an improvement of the original logit transformation. Certain reservations exist, however, in elimination of outliers because of the dispersion of the data points, and also because of the arbitrarily set thresholds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System

Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...

متن کامل

A Comparison between Different Editions of API650 Seismic Provisions for Cylindrical Steel Storage Tanks Considering the Fragility Curves

Seismic safety of liquid storage tanks is of considerable importance due to its application in different industries. In Iran, most of these storage tanks are designed based on API650 code provisions. Despite designing tanks according to API standard, the lesson learned from previous earthquakes, shows different kind of damage occurring on them. This study is an investigation on evaluating diffe...

متن کامل

Comparison between sodium hypochlorite and copper sulfate reducer in lightening of overexposed working length radiographs

Objectives: The aims of this study were to test whether lightening of the overexposed radiographs improve determination of endodontic files length and whether lightened radiographs are comparable with ideally exposed radiographs. Material and Methods: Four dried human skull coated with soft tissue-equivalent wax used for exposing radiographs of the upper molars. First, the endodontic file was p...

متن کامل

A Survey of Concurrency Control Algorithms in the Operating Systems

Concurrency control is one of the important problems in operation systems. Various studies have been reported to present different algorithms to address this problem, although a few attempts have been made to represent an overall view of the characteristics of these algorithms and comparison of their capabilities to each other. This paper presents a survey of the current methods for controlling...

متن کامل

A Survey of Concurrency Control Algorithms in the Operating Systems

Concurrency control is one of the important problems in operation systems. Various studies have been reported to present different algorithms to address this problem, although a few attempts have been made to represent an overall view of the characteristics of these algorithms and comparison of their capabilities to each other. This paper presents a survey of the current methods for controlling...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 1980