Reconstruction for Limited-Projection Fluorescence Molecular Tomography Based on a Double-Mesh Strategy
نویسندگان
چکیده
Limited-projection fluorescence molecular tomography (FMT) has short data acquisition time that allows fast resolving of the three-dimensional visualization of fluorophore within small animal in vivo. However, limited-projection FMT reconstruction suffers from severe ill-posedness because only limited projections are used for reconstruction. To alleviate the ill-posedness, a feasible region extraction strategy based on a double mesh is presented for limited-projection FMT. First, an initial result is rapidly recovered using a coarse discretization mesh. Then, the reconstructed fluorophore area in the initial result is selected as a feasible region to guide the reconstruction using a fine discretization mesh. Simulation experiments on a digital mouse and small animal experiment in vivo are performed to validate the proposed strategy. It demonstrates that the presented strategy provides a good distribution of fluorophore with limited projections of fluorescence measurements. Hence, it is suitable for reconstruction of limited-projection FMT.
منابع مشابه
Fast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملComparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملReconstruction for free-space fluorescence tomography using a novel hybrid adaptive finite element algorithm.
With the development of in-vivo free-space fluorescence molecular imaging and multi-modality imaging for small animals, there is a need for new reconstruction methods for real animal-shape models with a large dataset. In this paper we are reporting a novel hybrid adaptive finite element algorithm for fluorescence tomography reconstruction, based on a linear scheme. Two different inversion strat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016