Bicycle exercise stress in PET for assessment of coronary flow reserve: repeatability and comparison with adenosine stress.

نویسندگان

  • Christophe A Wyss
  • Pascal Koepfli
  • Krzysztof Mikolajczyk
  • Cyrill Burger
  • Gustav K von Schulthess
  • Philipp A Kaufmann
چکیده

UNLABELLED PET allows absolute measurements of myocardial blood flow (MBF). The aim of the present study was to evaluate the feasibility and repeatability of supine bicycle exercise stress, compared with standard adenosine stress, in PET. METHODS In 11 healthy volunteers, MBF was assessed at rest, during adenosine-induced (140 microg/kg/min over 7 min) hyperemia, and immediately after supine bicycle exercise (mean workload, 130 W, which is 70% of the predicted value) using PET and (15)O-H(2)O. The assessment was then repeated after 20 min. Coronary flow reserve (CFR) was calculated as hyperemic/resting MBF for adenosine stress and exercise stress. Repeatability was evaluated according to the method of Bland and Altman. RESULTS No significant differences were found between the paired resting MBF (1.22 +/- 0.16 vs. 1.26 +/- 0.21 mL/min/g; mean difference, 3% +/- 11%) and the hyperemic MBF with adenosine stress (5.13 +/- 0.74 vs. 4.97 +/- 1.05; mean difference, -4% +/- 14%) or exercise stress (2.35 +/- 0.66 vs. 2.25 +/- 0.61; mean difference, -4% +/- 19%). CFR was reproducible with adenosine stress (4.23 +/- 0.62 vs. 4.05 +/- 1.06, P = not statistically significant; mean difference, -5% +/- 19%) and exercise stress (1.91 +/- 0.46 vs. 1.80 +/- 0.44, P = not statistically significant; mean difference, -5% +/- 15%). Repeatability coefficients for MBF were 0.26 (rest), 1.34 (adenosine stress), and 0.82 (exercise stress) mL/min/g. CONCLUSION Assessment of CFR with (15)O-H(2)O and PET using bicycle exercise in the PET scanner is feasible and at least as repeatable as using adenosine stress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the long-term reproducibility of baseline and dobutamine-induced myocardial blood flow in patients with stable coronary artery disease.

UNLABELLED Although physical exercise is the preferred stimulus for cardiac stress testing, pharmacologic agents are useful in patients who are unable to exercise. Previous studies have demonstrated short-term repeatability of exercise and adenosine stress, but little data exist regarding dobutamine (Dob) stress or the long-term reproducibility of pharmacologic stressors in coronary artery dise...

متن کامل

Assessment of coronary flow reserve: comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography.

OBJECTIVES The study compared flow reserve indices by magnetic resonance imaging (MRI) with quantitative measures of coronary angiography and positron emission tomography (PET). BACKGROUND The noninvasive evaluation of myocardial flow by MRI has recently been introduced. However, a comparison to quantitative flow measurement as assessed by PET has not been reported in patients with coronary a...

متن کامل

Influence of altitude exposure on coronary flow reserve.

BACKGROUND Although no data exist on the effect of altitude exposure on coronary flow reserve (CFR), patients with coronary artery disease (CAD) are advised not to exceed moderate altitudes of approximately 2500 m above sea level. We studied the influence of altitude on myocardial blood flow (MBF) in controls and CAD patients. METHODS AND RESULTS In 10 healthy controls and 8 patients with CAD...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2003