Interfering ultraviolet-absorbing compounds as sources of error in common clinical chemistry tests.

نویسندگان

  • K S Warren
  • C D Scott
چکیده

Fourteen spot tests and color reactions were selected for their potential applicability to the problem of identifying urinary components separated by a high-resolution analytical system. These tests were screened with an inventory of 74 biochemicals of current interest. The results of this testing program are given and reveal the lack of specificity inherent in many tests which are sometimes assumed to be free of interference.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of dietary purine restriction, allupurinol, and oxipurinol on urinary excretion of ultraviolet-absorbing compounds.

We demonstrate that purine restriction is associated with a decreased excretion of a number of uv-absorbing compounds-including uric acid, hypoxanthine, xanthine, adenine, pseudouridine, and 5-acetylamino-6-amino-3methyluracil-indicating that these compounds originate, at least partly, exogenously. Administration of allopurinol and oxipurinol is associated with a decreased excretion of uric aci...

متن کامل

Interference in laboratory tests

Interference in clinical laboratory testing can create discrepancies in test results which can lead to patient harm.  In clinical chemistry, interference is defined as a cause of medically significant difference in the measurand test result due to another component or property of the sample. Interference by endogenous and exogenous substances with assays for clinical analytes is a common prob...

متن کامل

Analysis of Photosynthetic Characteristics and UV-B Absorbing Compounds in Mung Bean Using UV-B and Red LED Radiation

Mung bean has been reported to have antioxidant, antidiabetic, anti-inflammatory, and antitumor activities. Various factors have important effects on the types and contents of plant chemical components. In order to study quality of mung bean from different light sources, mung bean seedlings were exposed to red light-emitting diodes (LEDs) and ultraviolet-B (UV-B). Changes in the growth paramete...

متن کامل

Ultraviolet-absorbing compounds in urine of normal newborns and young children.

Ultraviolet-absorbing compounds excreted in the urine of normal newborns, infants, and children have been measured by high-pressure anion-exchange chromatography. The chromatograms increased in complexity with increasing age of the subject. Preliminary data indicate thatthe excretion of pseudouridine and uridine was significant’y higher in newborns and infants than in older children and adults....

متن کامل

Separation and identification of urinary constituents by use of multiple-analytical techniques.

High-pressure anion-exchange chromatography with gradient elution has been used to resolve ultraviolet-absorbing constituents from normal and pathologic specimens of human urine. We have identified 50 of these constituents by using multiple-analytical techniques. Ultraviolet spectral maxima, gas chromatographic methylene unit (MU) retention values (for trimethylsilyl derivatives), and the major...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 15 12  شماره 

صفحات  -

تاریخ انتشار 1969