Apparent Diffusion Coefficient Mapping Using a Multi-Shot Spiral MRI Sequence of the Rat Brain

نویسندگان

  • Tomokazu Numano
  • Koji Hyodo
  • Naotaka Nitta
  • Junichi Hata
  • Nobuaki Iwasaki
  • Kazuhiro Homma
چکیده

Purpose: Commonly used diffusion weighted (DW) imaging such as DW spin echo (SE) type echo planar imaging (DW-SE-EPI) is known to be a snapshot-like acquisition and to have a relatively high signal-to-noise ratio. Spiral MRI sequence (SPIRAL) has characteristics similar to these of EPI, but it has rarely been used for diffusion-weighted imaging (DWI). In vivo DW-SPIRAL of the rat brain has almost never been reported. Our purpose in this study was to examine the potential of SE-type two-dimensional (2D) multi-shot spiral acquisition MRI for apparent diffusion coefficient (ADC) mapping of the rat brain in vivo. Materials and Methods: We made an SE-type DW-2D-spiral MRI sequence (DW-SPIRAL) which was prepared on a 2.0-T animal-experiment MR scanner. Comparing the phantom experimental result of DW-SPIRAL with the phantom experimental result of DW SE-type echo-planar imaging (DW-SE-EPI) and conventional DW spin echo imaging (DW-SE), we estimated the characteristics of DW-SPIRAL and assessed the clinical application of DW-SPIRAL in an animal experiment on the rat brain. Results: There was not much difference between the calculated water/glycerol phantom diffusion coefficient of DW-SPIRAL and the calculated diffusion coefficient of DW-SE. This result shows that the DW-SPIRAL sequence is appropriate for use in diffusion weighted imaging. There were fewer phantom image distortions and ghosting artifacts with DW-SPIRAL than with DW-SE-EPI, and this tendency was similar in the animal experiment on the rat brain. Conclusion: The DW-SPIRAL sequence had been successfully tested in phantom experiments and rat brain experiments. It has been demonstrated that the DW-SPIRAL sequence is capable of producing in vivo rat brain DWI. Corresponding author.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.

PURPOSE To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-weighted imaging (DWI) in the brain with submillimeter in-plane resolution. MATERIALS AND METHODS A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction ...

متن کامل

The Utility of Diffusion Weighted Magnetic Resonance Imaging in Detection of the Origin of the Brain Solid Metastatic Tumors

Background: Early diagnosis of brain tumors has significant effect on the treatment process. Brain metastatic tumors are usually diagnosed following the neurological symptoms in patients or incidentally after Computerized Tomography (CT) scan and Magnetic Resonance Imaging (MRI) requests of the brain. Objectives: Implementation of a new method for being informed about the origin of brain tumors...

متن کامل

Diffusion tensor mapping of the human brain using single-shot line scan imaging.

A recently developed single-shot line scan imaging technique for diffusion measurements (Finsterbusch and Frahm, Magn Reson Med 1999;42:772-778) was extended to full diffusion tensor mapping of the human brain. Because the sequence acquires stimulated echoes from individual columns of magnetization ("lines"), the approach is affected neither by spatial aliasing when studying inner volumes nor b...

متن کامل

Fast and tissue-optimized mapping of magnetic susceptibility and T2* with multi-echo and multi-shot spirals

Gradient-echo MRI of resonance-frequency shift and T2* values exhibit unique tissue contrast and offer relevant physiological information. However, acquiring 3D-phase images and T2* maps with the standard spoiled gradient echo (SPGR) sequence is lengthy for routine imaging at high-spatial resolution and whole-brain coverage. In addition, with the standard SPGR sequence, optimal signal-to-noise ...

متن کامل

Spiral MRI on rat brain and rat heart at 7 Tesla

INTRODUCTION: Although quite similar in many aspects, the spiral imaging technique features several advantages over Echo Planar Imaging (EPI). Especially, (i) higher acquisition speed, due to a more efficient use of the gradient hardware (the two in-plane channels operate simultaneously, applying waveforms optimized to fully exploit the amplifiers), (ii) very short minimum echo time (TE), with ...