Audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI
نویسندگان
چکیده
The purpose of this study was to test the hypothesis that audiovisual (AV) biofeedback can improve image quality and reduce scan time for respiratory-gated 3D thoracic MRI. For five healthy human subjects respiratory motion guidance in MR scans was provided using an AV biofeedback system, utilizing real-time respiratory motion signals. To investigate the improvement of respiratory‐gated 3D MR images between free breathing (FB) and AV biofeedback (AV), each subject underwent two imaging sessions. Respiratory‐related motion artifacts and imaging time were qualitatively evaluated in addition to the reproducibility of external (abdominal) motion. In the results, 3D MR images in AV biofeedback showed more anatomic information such as a clear distinction of diaphragm, lung lobes and sharper organ boundaries. The scan time was reduced from 401±215 s in FB to 334±94 s in AV (p-value 0.36). The root mean square variation of the displacement and period of the abdominal motion was reduced from 0.4±0.22 cm and 2.8±2.5 s in FB to 0.1±0.15 cm and 0.9±1.3 s in AV (pvalue of displacement <0.01 and p-value of period 0.12). This study demonstrated that audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI. These results suggest that AV biofeedback has the potential to be a useful motion management tool in medical imaging and radiation therapy procedures.
منابع مشابه
High-resolution whole-heart angiography with compressed sensing and 3D respiratory motion compensation in 5 minutes
Background The electrocardiogram and respiratory-gated 3D steadystate free precession (3D-SSFP) sequence acquired during free-breathing generates a high-resolution anatomic datasets of the entire thorax, allowing for a comprehensive evaluation of intracardiac, coronary, and vascular abnormalities. An important limitation of 3D-SSFP, however, is its long imaging time during which the patient’s h...
متن کامل3D Coronary MRA with 2D beat-to-beat translational and bin-to-bin affine respiratory motion correction using a golden radial image navigator
Figure 2 – Reformatted images showing the main coronary arteries of two subjects. Subject 1: 2D Affine + translational motion correction gives superior image quality compared to both 2D translational correction and a gated scan (with ~3x reduction in scan time). Subject 2: 2D motion correction gives similar image quality to the gated scan with ~2x reduction in scan time. Affine correction shows...
متن کاملAudiovisual biofeedback guided breath-hold improves lung tumor position reproducibility and volume consistency
Purpose Respiratory variation can increase the variability of tumor position and volume, accounting for larger treatment margins and longer treatment times. Audiovisual biofeedback as a breath-hold technique could be used to improve the reproducibility of lung tumor positions at inhalation and exhalation for the radiation therapy of mobile lung tumors. This study aimed to assess the impact of a...
متن کاملCommissioning and quality assurance for a respiratory training system based on audiovisual biofeedback
A respiratory training system based on audiovisual biofeedback has been implemented at our institution. It is intended to improve patients' respiratory regularity during four-dimensional (4D) computed tomography (CT) image acquisition. The purpose is to help eliminate the artifacts in 4D-CT images caused by irregular breathing, as well as improve delivery efficiency during treatment, where resp...
متن کاملThe impact of breathing guidance and prospective gating during thoracic 4DCT imaging: an XCAT study utilizing lung cancer patient motion.
Two interventions to overcome the deleterious impact irregular breathing has on thoracic-abdominal 4D computed tomography (4DCT) are (1) facilitating regular breathing using audiovisual biofeedback (AVB), and (2) prospective respiratory gating of the 4DCT scan based on the real-time respiratory motion. The purpose of this study was to compare the impact of AVB and gating on 4DCT imaging using t...