[Study of aliasing ERROR with SENSE in body diffusion image using single-shot EPI at 3T].
نویسندگان
چکیده
Magnetic field inhomogeneity causes artifacts in MRI. For example, in single-shot echo-planar imaging (EPI), they often appear as severe geometric distortions along the phase-encoding direction. Sensitivity encoding (SENSE) is useful in reducing the distortion in EPI since it only acquires partial k-space data using multiple receiver channels. In SENSE, a reference scan usually needs to be performed to create a sensitivity profile of each receiver channel. Gradient echo (GRE) sequences are often used in the reference scan. In diffusion-weighted imaging (DWI) using single-shot EPI with SENSE, non-negligible aliasing artifacts often remain in the reconstructed images. We suppose that these artifacts result from misregistration between the reference images acquired using GRE sequences and the DWI acquired using EPI. In this study, we used two types of acquisition methods to create sensitivity profiles, GRE sequences and EPI, and have compared the residual artifacts in the reconstructed images. The sensitivity profiles were created from the data acquired using the GRE and EPI sequences. Artifacts were reduced when EPI sensitivity profiles were used. This resulted from the fact that off-resonance effects, e.g., magnetic field inhomogeneity, susceptibility, and chemical shift, often cause severe image distortion in EPI, and, therefore, there is misregistration between images reconstructed from the data acquired using GRE and EPI sequences. Our study suggests that EPI sensitivity profiles be used when imaging data are acquired using a single-shot EPI with SENSE, although GRE sensitivity profiles have often been used in practice.
منابع مشابه
Multi-Shot, Diffusion-Weighted Imaging at 3T using Readout-Segmented EPI and GRAPPA
D. A. Porter, R. M. Heidemann MR Applications Development, Siemens Medical Solutions, Erlangen, Germany Introduction Diffusion-weighted, single-shot EPI suffers from considerable susceptibility-based distortion artefact at 3T. Although the effects can be mitigated by using a partially parallel imaging (PPA) technique to reduce the effective echo-spacing [1], there are significant residual artef...
متن کاملHigh-resolution diffusion weighted MRI enabled by multi-shot EPI with multiplexed sensitivity-encoding
Nan-kuei Chen, Arnaud Guidon, Hing-Chiu Chang, and Allen W Song Brain Imaging and Analysis Center, Duke University, Durham, NC, United States Target audience: Neuroimaging researchers and clinicians who are interested in high-resolution diffusion-weighted imaging Purpose: The goal of this study is to develop a novel post-processing algorithm, enabling diffusion weighted imaging (DWI) of high-qu...
متن کاملReduction of Aliasing Artifacts in Diffusion-Weighted PROPELLER Imaging
Introduction Diffusion imaging is typically performed in axial planes. This is largely due to its reliance on single-shot echo-planar imaging (EPI) which suffers from increased image distortion in sagittal and coronal planes because of concomitant gradient fields [1-2], especially with strong gradients and/or at relatively low B0-fields (including 1.5T). Diffusion-weighted (DW) imaging in non-a...
متن کاملJoint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.
Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...
متن کاملZoomed EPI-DWI of the Pancreas Using Two-Dimensional Spatially-Selective Radiofrequency Excitation Pulses
BACKGROUND Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 64 12 شماره
صفحات -
تاریخ انتشار 2008