Acoustic simulations of combined electric and acoustic hearing (EAS).

نویسندگان

  • Michael F Dorman
  • Anthony J Spahr
  • Philipos C Loizou
  • Cindy J Dana
  • Jennifer S Schmidt
چکیده

OBJECTIVE Our aim was to explore the consequences for speech understanding of leaving a gap in frequency between a region of acoustic hearing and a region stimulated electrically. Our studies were conducted with normal-hearing listeners, using an acoustic simulation of combined electric and acoustic (EAS) stimulation. DESIGN Simulations of EAS were created by low-pass filtering speech at 0.5 kHz (90 dB octave roll-off) and adding amplitude-modulated sine waves at higher frequencies. The gap in frequency between acoustic and simulated electric hearing was varied over the range 0.5 kHz to 3.2 kHz. Stimuli included sentences in quiet, sentences in noise, and consonants and vowels. Three experiments were conducted with sample sizes of 12 listeners. RESULTS Scores were highest in conditions that minimized the frequency gap between acoustic and electric stimulation. In quiet, vowels and consonant place of articulation showed the most sensitivity to the frequency gap. In noise, scores in the simulated EAS condition were higher than the sum of the scores from the acoustic-only and simulated electric-only conditions. CONCLUSIONS Our results suggest that both deep and shallow insertions of electrodes could improve the speech understanding abilities of patients with residual hearing to 500 Hz. However, performance levels will be maximized if the gap between acoustic and electric stimulation is minimized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Musical Instrument Recognition in Combined Electric and Acoustic Cochlear Implant Simulations

The present study investigated listeners’ performance in a closed-set musical instrument recognition task through simulations of a cochlear implant (CI) and electric-acoustic stimulation (EAS), where the use of a CI is supplemented by a hearing aid to access low-frequency residual hearing. The recognition rates varied across the different musical instruments, with higher scores for instruments ...

متن کامل

Cochlear Implants and Hearing Preservation Advances in Oto-Rhino-Laryngology

Hearing preservation after cochlear implantation and combined electric acoustic stimulation (EAS) in the same ear has reduced the gap between prosthetic hearing rehabilitation with hearing aids and cochlear implants. This has increased the possibility of successful hearing rehabilitation for patients. This paper describes the history of hearing preservation after cochlear implantation. Indicati...

متن کامل

Speech Perception With Combined Electric-Acoustic Stimulation: A Simulation and Model Comparison.

OBJECTIVE The aim of this study is to simulate speech perception with combined electric-acoustic stimulation (EAS), verify the advantage of combined stimulation in normal-hearing (NH) subjects, and then compare it with cochlear implant (CI) and EAS user results from the authors' previous study. Furthermore, an automatic speech recognition (ASR) system was built to examine the impact of low-freq...

متن کامل

Partial deafness cochlear implantation (PDCI) and electric-acoustic stimulation (EAS).

The purposes of this paper are to (1) review briefly the experience to date with combined EAS for patients with some residual, low-frequency hearing; and (2) describe the further results that have been obtained with this combination for patients with higher levels of residual hearing at low frequencies, termed 'PDCI'. In broad terms, PDCI and combined EAS have produced large improvements in the...

متن کامل

Combined electric and acoustic stimulation of the auditory system: results of a clinical study.

Combined electric and acoustic stimulation (EAS) of the auditory system is a new therapy for patients with severe to profound high- and mid-frequency hearing loss but remaining low-frequency hearing. In a prospective study, 13 patients with low-frequency hearing of better than 60 dB below 1 kHz were implanted with a MED-EL COMBI 40+ cochlear implant. Pure tone thresholds as well as monosyllabic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2005