Effects of teriparatide on cementless bipolar hemiarthroplasty in patients with osteoporotic femoral neck fractures

نویسندگان

  • Tsan-Wen Huang
  • Kuo-Chin Huang
  • Shih-Jie Lin
  • Po-Yao Chuang
  • Hsin-Nung Shih
  • Mel S. Lee
  • Robert Wen-Wei Hsu
  • Wun-Jer Shen
چکیده

BACKGROUND For osteoporotic femoral neck fractures, suitable bone-implant stability is critical for pain relief, early return to daily activities and reduction of complications. Teriparatide (parathyroid hormone [PTH1-34]) can improve bone-implant stability in some basic studies. However it's use in osteoporotic femoral neck fractures treated by cementless hemiarthroplasties for the beneficial effects on bone-implant stability is sparse in the literature. The aim of this study was to determine if post-operative teriparatide administration can reduce femoral stem migration and improve early functional recovery and health-related quality of life (HRQoL). METHODS Between 2010 and 2014, patients with osteoporotic femoral neck fracture who underwent cementless bipolar hemiarthroplasty were included into this retrospective cohort study. Group A included patients treated with cementless bipolar hemiarthroplasty only; Group B patients had additional teriparatide. Demographic data, complications, radiographic and functional outcomes as well as health-related quality of life (HRQoL) were compared. RESULTS There were 52 hips in group A (no teriparatide) and 40 hips in group B (patient who received teriparatide). The subsidence of the femoral stem tended to be significantly decreased in the teriparatide group at 6 and 12 weeks post-operatively (p = 0.003 and p = 0.008, respectively). The Harris Hip Score (HHS) increased significantly from pre-operation to 6 weeks post-operatively and thereafter up to one year in both groups. However, there were no significant differences in terms of subsequent fracture, mortality, HHS, and HRQoL between two groups during the entire study period. CONCLUSIONS Teriparatide significantly reduces the subsidence of the cementless femoral stem in elderly patients in the early post-operative period, but this benefit does not reflect better functional outcomes and HRQoL. Further prospective randomized large-scale cohort study is warranted for evidence-based recommendations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bipolar Hemarthroplasty Using Cementless Conical Stem for Treatment of Dorr Type B and C Femoral Neck Fracture

PURPOSE The current study aims to evaluate the clinical and the radiological outcome of bipolar hemiarthroplasty using cementless cone stem to treat osteoporotic femoral neck fracture and compare the results according to the proximal femur geometry. MATERIALS AND METHODS Seventy-five hips (75 patients) that underwent bipolar hemiarthroplasty with cementless cone stem between September 2006 an...

متن کامل

Comparative Study of Bipolar Hemiarthroplasty for Femur Neck Fractures Treated with Cemented versus Cementless Stem

PURPOSE To compare and analyze clinical and radiologic outcomes of cemented versus cementless bipolar hemiarthroplasty for treatment of femur neck fractures. MATERIALS AND METHODS A total of 180 patients aged 65 years and over older who underwent bipolar hemiarthroplasty for treatment of displaced femur neck fractures (Garden stage III, IV) from March 2009 to February 2014 were included in th...

متن کامل

Proximally coated cementless bipolar hemiarthroplasty in Dorr type C bone.

The current study was conducted to examine the clinical and radiographic outcomes of cementless bipolar arthroplasty in patients who had type C bone at the time of the procedure. A total of 87 patients (105 hips) who had type C femora and had undergone cementless bipolar hemiarthroplasty with a proximally coated cementless prosthesis for the treatment of displaced femoral neck fractures at a si...

متن کامل

Cemented versus cementless hemiarthroplasty for femoral neck fractures in the elderly.

PURPOSE To compare cemented versus cementless bipolar hemiarthroplasty in terms of operating time, blood loss, pain, functional outcome, morbidity, and mortality. METHODS Medical records of 207 patients aged ≥ 60 years who underwent bipolar hemiarthroplasty for displaced femoral neck fracture using a cemented (n=96) or cementless (n=111) prosthesis were reviewed. Postoperative thigh pain, amb...

متن کامل

Bipolar versus fixed-head hip arthroplasty for femoral neck fractures in elderly patients

Between 2002 and 2007, fifty elderly patients with displaced femoral neck fractures were treated with hip replacement at Emergency Hospital, Mansoura University. Patients were randomly selected, 25 patients had either cemented or cementless bipolar prosthesis, and another 25 patients had either cemented or cementless fixed-head prosthesis. There were 34 women and 16 men with an average age of 6...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016