Strain-rate dependent stiffness of articular cartilage in unconfined compression.
نویسندگان
چکیده
The stiffness of articular cartilage is a nonlinear function of the strain amplitude and strain rate as well as the loading history, as a consequence of the flow of interstitial water and the stiffening of the collagen fibril network. This paper presents a full investigation of the interplay between the fluid kinetics and fibril stiffening of unconfined cartilage disks by analyzing over 200 cases with diverse material properties. The lower and upper elastic limits of the stress (under a given strain) are uniquely established by the instantaneous and equilibrium stiffness (obtained numerically for finite deformations and analytically for small deformations). These limits could be used to determine safe loading protocols in order that the stress in each solid constituent remains within its own elastic limit. For a given compressive strain applied at a low rate, the loading is close to the lower limit and is mostly borne directly by the solid constituents (with little contribution from the fluid). In contrast, however in case of faster compression, the extra loading is predominantly transported to the fibrillar matrix via rising fluid pressure with little increase of stress in the nonfibrillar matrix. The fibrillar matrix absorbs the loading increment by self-stiffening: the quicker the loading the faster the fibril stiffening until the upper elastic loading limit is reached. This self-protective mechanism prevents cartilage from damage since the fibrils are strong in tension. The present work demonstrates the ability of the fibril reinfored poroelastic models to describe the strain rate dependent behavior of articular cartilage in unconfined compression using a mechanism of fibril stiffening mainly induced by the fluid flow.
منابع مشابه
A Theoretical Study Of The Mechanical Response Of Articular Cartilage To Impact Loading
INTRODUCTION Experimentally, the stresses of articular cartilage have been found to depend on the loading rate [1,2]. Theoretically, the short-term transient behavior of cartilage in unconfined compression has been explored at strain rates of 0.01, 0.1 and 1%/s using a poroviscoelastic model [3]. In the present work, the transient stress-strain relationship, the dependence of stiffness on tissu...
متن کاملPredicting Articular Cartilage Behavior with a Non-Linear Microstructural Model
We report here on a non-linear poroelastic model for the mechanical response of collagenous soft tissues such as articular cartilage. The tissue consists of a porous, fibril-reinforced, hyperelastic solid, saturated with an incompressible fluid, and Darcy's law governs solid-fluid interaction. The solid matrix is characterized by the isotropic hyperfoam strain energy function and its permeabili...
متن کاملUnconfined compression of articular cartilage: nonlinear behavior and comparison with a fibril-reinforced biphasic model.
Mechanical behavior of articular cartilage was characterized in unconfined compression to delineate regimes of linear and nonlinear behavior, to investigate the ability of a fibril-reinforced biphasic model to describe measurements, and to test the prediction of biphasic and poroelastic models that tissue dimensions alter tissue stiffness through a specific scaling law for time and frequency. D...
متن کاملInvestigation of mechanical behavior of articular cartilage by fibril reinforced poroelastic models.
The fibril reinforced poroelastic models have been found successful in describing some mechanical behaviors of articular cartilage in unconfined compression that were not understood previously, including the strong and nonlinear transient response, the strain-magnitude and strain-rate dependent cartilage stiffness and the depth-varying stresses and strains. It has been demonstrated that a bette...
متن کاملTime and depth dependent Poisson's ratio of cartilage explained by an inhomogeneous orthotropic fiber embedded biphasic model.
A time- and depth-dependent Poisson's ratio has been observed during unconfined compression experiments on articular cartilage, but existing cartilage models have not fully addressed these phenomena. The goal of this study was to develop a model which is able to predict and explain these phenomena, while also being able to fit other experimental scenarios on full depth cartilage specimens such ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 125 2 شماره
صفحات -
تاریخ انتشار 2003