SU-E-T-216: A Clinical Dosimetry Analysis of Total Body Irradiation for Leukemia Patients.
نویسندگان
چکیده
PURPOSE Perform a retrospective dosimetry study of total body irradiation (TBI) on leukemia and bone marrow transplant patients. METHODS The in vivo dosimetry data of 129 patients treated with TBI between 2008 and 2011 were retrieved from the database and analyzed. These patients were mostly treated with the regime of a single fraction or 6 fractions with some exceptions of 8-fraction or 2-fraction treatments depending on the protocols that were applied. For every fraction of treatment, 10 pairs of diode dosimeters were used to monitor the doses to the mid-line of head, neck, arms, mediastinum, left lung, right lung, umbilicus, thigh, knee, and angle for both AP and PA fields. The doses to the midline of the above body parts were considered to be the average of the AP and PA readings of each diode pair. Dose deviation from the prescribed value for each body part was studied by plotting the histogram of the frequency versus deviation and comparing this with the dose delivered to the midline of the umbilicus to where the dose was prescribed. The correlation of dose deviation to body part thickness was also studied. RESULTS The dose differences between measurement and prescription for all body parts are mostly less than 10%. The dose inhomogeneity on different body parts could be manually improved by using compensators but the method is cumbersome. The dose deviation in many histograms ranging from about -10% to 10% indicates some incongruity of dose distribution. This could be due to the method of using lead compensators for a manual dose adjustment which could not ideally compensate different body thicknesses everywhere. CONCLUSION The conventional TBI could give uniform dose to the major body parts under the in vivo dosimetry monitoring at the level of 10%, but the treatment procedure is cumbersome and time consuming.
منابع مشابه
Prophylactic Radiotherapy in Acute Lymphocytics Leukemia of Children
The concept of CNS preventive therapy in childhood all is based on the assumption that undetectable CNS leukemia is present in most patients at the time of diagnosis, residing in that "sdnctuary site" protected by the blood-brain barrier from cytotoxic concentrations of most systemically administered antileukemic agents. Studies in the 1960s demonstrated that administration of 2400 rad cranial...
متن کاملClinical application of lying-on-the-floor total skin electron irradiation for frail patients with cutaneous lymphoma: An emphasis on the importance of in vivo dosimetry
Total skin electron irradiation (TSEI) is an effective option for cutaneous T-cell lymphoma (CTCL). Two conventional methods used to deliver TSEI are the Stanford multiple dual field technique and the McGill rotational technique; however, both techniques require patients to stand for 10 to 30 minutes and cannot be used in nonambulatory patients. Our group has previously described technical para...
متن کاملDiode calibration for dose determination in total body irradiation
Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...
متن کاملA technique for pediatric total skin electron irradiation
BACKGROUND Total skin electron irradiation (TSEI) is a special radiotherapy technique which has generally been used for treating adult patients with mycosis fungoides. Recently, two infants presented with leukemia cutis isolated to the skin requiring TSEI. This work discusses the commissioning and quality assurance (QA) methods for implementing a modified Stanford technique using a rotating har...
متن کاملA translational couch technique for total body irradiation
We have constructed a computer controlled translational couch to administer total body irradiation reproducibly and safely. The system has replaced the previous stationary anterior-posterior technique in our institution and 30 plus patients have been treated with it so far. In this technique, patients comfortably lie on a couch in supine and prone positions and are transported slowly through a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 40 6Part13 شماره
صفحات -
تاریخ انتشار 2013