Validated chromatographic methods for simultaneous determination of tolfenamic acid and its major impurities.

نویسندگان

  • Nada S Abdelwahab
  • Nouruddin W Ali
  • Marco M Zaki
  • M Abdelkawy
چکیده

Two accurate, selective and precise chromatographic methods, namely thin-layer chromatography (TLC)-densitometric method and reversed phase high-performance liquid chromatography (RP-HPLC) method, were developed and validated for the simultaneous determination of tolfenamic acid (TOL) and its two major impurities, 2-chlorobenzoic acid (CBA) and 3-chloro-2-methylaniline (CMA), which are also reported to be its related substances. The developed TLC-densitometric method depended on separation and quantitation of the studied drugs on silica gel 60F254 TLC plates. Hexane:chloroform:acetone:acetic acid (75:25:20:0.1, v/v/v/v) was used as a developing system and the separated bands were UV-scanned at 240 nm. Linear relationships were obtained in the range of 10-100 µg band(-1) for the drug and in the range of 0.1-1 µg band(-1) for the studied impurities. The developed RP-HPLC depended on chromatographic separation of the studied drugs on a C18 column using 0.05 M KH2PO4 buffer (pH 3):acetonitrile (45:55, v/v) as a mobile phase delivered at constant flow rate of 1 mL min(-1) with UV detection at 230 nm. Calibration curves for TOL and the two impurities were constructed over the concentration ranges of 10-100 µg mL(-1) for TOL and 0.01-0.1 µg mL(-1) for both CBA and CMA. Factors affecting the developed methods have been studied and optimized. Further, methods validation has been carried out according to International Conference on Harmonization guidelines. The proposed methods were successfully applied for determination of the studied drug in its bulk powder and in pharmaceutical formulation. The methods showed no significant difference when compared with the reported RP-HPLC one. The developed methods have advantages of being more sensitive and specific than the published methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

Multi-residue determination of non-steroidal anti-inflammatory drug residues in animal serum and plasma by HPLC and photo-diode array detection.

The European Union regulated the use of non-steroidal anti-inflammatory drugs (NSAIDs) in animal production and set the official analytical controls to detect their residues in plasma, serum, and milk within the frame of national monitoring programs in each member state. In this work, a multi-residue reversed-phase high-performance liquid chromatography with diode array detector (DAD) method is...

متن کامل

Simultaneous determination of hydrochlorothiazide and benazepril hydrochloride or amiloride hydrochloride in presence of hydrochlorothiazide impurities: chlorothiazide and salamide by HPTLC method.

Simple, selective and sensitive high-performance thin layer chromatographic (HPTLC) method has been developed and validated for the simultaneous determination of hydrochlorothiazide (HCZ) in the presence of its impurities (chlorothiazide (CT) and salamide (DSA)), in two quaternary mixtures with benazepril hydrochloride (BZ) or amiloride hydrochloride (AM). The separation was carried out on HPTL...

متن کامل

Quality Control and Standardization of Rabeprazole Tablets

Rabeprazole sodium is a new stable pharmaceutical composition developed by us in tablet form, consisting of rabeprazole sodium as active ingredient, excipients, a separating layer and enteric coating. The manufacturing method involves pressing with preliminary wet granulation. In this work, a method was developed for the quantitative determination of rabeprazole sodium in tablets with simultane...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2015