Are Western Knee Designs Dimensionally Correct for Korean Women? A Morphometric Study of Resected Femoral Surfaces during Primary Total Knee Arthroplasty
نویسندگان
چکیده
BACKGROUND The purpose of this study was to determine the shape of the distal femur of Korean women compared with the prostheses currently available in Korea. METHODS Morphometric data (5 parameters) were measured in 356 resected femurs of Korean women undergoing primary total knee arthroplasty (TKA) utilizing the LCS knee implant (DePuy). The data were then compared with 5 additional contemporary TKA implant systems. RESULTS Implant designs based on Caucasian population data do not ideally match the distal femoral morphology of Korean women. Overhang at the anterior mediolateral width was observed in 84.8% for the LCS while a gender-specific implant resulted in undercoverage of the bone in 86%. Posterior overhang was observed in up to 51.2%. Most implant designs have a narrower intercondylar notch than the morphologic data of Korean women. CONCLUSIONS Since there is some difference between the shape of distal femur of Korean women and that of the implants, surgeons should have this in mind when selecting an implant for a patient. These data may also be used as a guideline for future prosthetic design options for Korean women population.
منابع مشابه
Primary posterior stabilized total knee arthroplasty: analysis of different instrumentation
BACKGROUND Intercondylar femoral bone removal during posterior stabilized (PS) total knee arthroplasty (TKA) makes many cruciate substituting implant designs less appealing than cruciate retaining implants. Bone stock conservation is considered fundamental in the prevision of future revision surgeries. The purpose of this study was to compare the quantity of intercondylar bone removable during ...
متن کاملAnthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population
Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...
متن کاملResected femoral anthropometry for design of the femoral component of the total knee prosthesis in a Korean population
We measured the mediolateral (ML) and anteroposterior (AP) length, height and widths of the anterior, posterior and inferior section of the resected distal femurs using three dimensional computer tomographic measurements in 200 knees from 100 cadavers. We also calculated the aspect ratio (ML/AP) and compared the measured parameters with that of six conventionally used total knee femoral prosthe...
متن کاملAnalysis of differences in bone removal during femoral box osteotomy for primary total knee arthroplasty.
PURPOSE this study was conducted to compare the quantity of intercondylar bone removed during femoral box osteotomy for implantation of three contemporary posterior stabilized (PS) total knee arthroplasty designs: Sigma PS (DePuy), Vanguard (Biomet) and Persona (Zimmer). METHODS we compared the maximum volumetric bone resection required for the housing of the PS mechanism of these three desig...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کامل