Evaluation of the 3D Finite Element Method Using a Tantalum Rod for Osteonecrosis of the Femoral Head

نویسندگان

  • Jingsheng Shi
  • Jie Chen
  • Jianguo Wu
  • Feiyan Chen
  • Gangyong Huang
  • Zhan Wang
  • Guanglei Zhao
  • Yibing Wei
  • Siqun Wang
چکیده

BACKGROUND The aim of this study was to contrast the collapse values of the postoperative weight-bearing areas of different tantalum rod implant positions, fibula implantation, and core decompression model and to investigate the advantages and disadvantages of tantalum rod implantation in different ranges of osteonecrosis in comparison with other methods. MATERIAL AND METHODS The 3D finite element method was used to establish the 3D finite element model of normal upper femur, 3D finite element model after tantalum rod implantation into different positions of the upper femur in different osteonecrosis ranges, and other 3D finite element models for simulating fibula implant and core decompression. RESULTS The collapse values in the weight-bearing area of the femoral head of the tantalum rod implant model inside the osteonecrosis area, implant model in the middle of the osteonecrosis area, fibula implant model, and shortening implant model exhibited no statistically significant differences (p>0.05) when the osteonecrosis range was small (60°). The stress values on the artificial bone surface for the tantalum rod implant model inside the osteonecrosis area and the shortening implant model exhibited statistical significance (p<0.01). CONCLUSIONS Tantalum rod implantation into the osteonecrosis area can reduce the collapse values in the weight-bearing area when osteonecrosis of the femoral head (ONFH) was in a certain range, thereby obtaining better clinical effects. When ONFH was in a large range (120°), the tantalum rod implantation inside the osteonecrosis area, shortening implant or fibula implant can reduce the collapse values of the femoral head, as assessed by other methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome after tantalum rod implantation for treatment of femoral head osteonecrosis

BACKGROUND AND PURPOSE Tantalum rod implantation has recently been proposed for treatment of early stages of femoral head osteonecrosis.The purpose of our study was to report the early results of its use in pre- and post-collapse stages of the disease. METHODS We studied prospectively 27 patients who underwent tantalum rod implantation for treatment of nontraumatic femoral head osteonecrosis ...

متن کامل

Structural Efficacy of a Novel Porous Tantalum Implant for Osteonecrosis Grafting

Introduction: Vascularized fibular grafting is a promising treatment for femoral head osteonecrosis (ON), the rationale in part being to support the subchondral plate during structural reconstitution of the underlying (weakened) cancellous bone. Unfortunately, donor site morbidity is appreciable, including weakness, discomfort, and sensory abnormalities. An implant made from porous tantalum (He...

متن کامل

Tantalum rod implantation and vascularized iliac grafting for osteonecrosis of the femoral head.

Osteonecrosis of the femoral head is a progressive disease. Without operative intervention, it most often results in collapse and deterioration of the joint. Many joint-preserving surgeries have been implemented, but no uniform treatment exists. The authors report a modified technique of tantalum rod implantation combined with vascularized iliac grafting for the treatment of osteonecrosis of th...

متن کامل

Effect of Osteonecrosis Intervention Rod Versus Core Decompression Using Multiple Small Drill Holes on Early Stages of Necrosis of the Femoral Head: A Prospective Study on a Series of 60 Patients with a Minimum 1-Year-Follow-Up

INTRODUCTION The conventional CD used 10 mm drill holes associated with a lack of structural support. Thus, alternative methods such as a tantalum implant, small drill holes, and biological treatment were developed to prevent deterioration of the joint. The treatment of CD by multiple 3.2 mm drill holes could reduce the femoral neck fracture and partial weight bearing was allowed. This study wa...

متن کامل

Autologous Bone Marrow Mesenchymal Stem Cells Associated with Tantalum Rod Implantation and Vascularized Iliac Grafting for the Treatment of End-Stage Osteonecrosis of the Femoral Head

Tantalum rod implantation with vascularized iliac grafting has been reported to be an effective method for the treatment of young patients with osteonecrosis of the femoral head (ONFH) to avert the need for total hip arthroplasty (THA). However, there have been unsatisfactory success rates for end-stage ONFH. The authors describe a modified technique using bone marrow mesenchymal stem cells (BM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2014