Evaluation of the Olympus AU-510 analyser
نویسندگان
چکیده
The selective multitest Olympus AU-510 analyser was evaluated according to the recommendations of the Comision de Instrumentacion de la Sociedad Española de Quimica Clinica and the European Committee for Clinical Laboratory Standards. The evaluation was carried out in two stages: an examination of the analytical units and then an evaluation in routine work conditions. The operational characteristics of the system were also studied.THE FIRST STAGE INCLUDED A PHOTOMETRIC STUDY: dependent on the absorbance, the inaccuracy varies between +0.5% to -0.6% at 405 nm and from -5.6% to 10.6% at 340 nm; the imprecision ranges between -0.22% and 0.56% at 405 nm and between 0.09% and 2.74% at 340 nm. Linearity was acceptable, apart from a very low absorbance for NADH at 340 nm; and the imprecision of the serum sample pipetter was satisfactory.TWELVE SERUM ANALYTES WERE STUDIED UNDER ROUTINE CONDITIONS: glucose, urea urate, cholesterol, triglycerides, total bilirubin, creatinine, phosphate, iron, aspartate aminotransferase, alanine aminotransferase and gamma-glutamyl transferase.The within-run imprecision (CV%) ranged from 0.67% for phosphate to 2.89% for iron and the between-run imprecision from 0.97% for total bilirubin to 7.06% for iron. There was no carryover in a study of the serum sample pipetter. Carry-over studies with the reagent and sample pipetters shows some cross contamination in the iron assay.
منابع مشابه
Analytical performance of the selective, automatic multianalyser Olympus AU 5031
The analytical performance of the selective, automatic multianalyser Olympus AU 5031 was evaluated over four months and assessed for practicability for another eight months. The evaluation followed the ECCLS guidelines. Twenty routine parameters were measured. In addition, sodium and potassium were determined on an attached flame photometric unit. Both the agreement between the eights photomete...
متن کاملAnalytical performance of the selective multianalyser Olympus AU 5200
The analytical performance of a selective, automatic multianalyser- the Olympus A U5200 - was tested and assessed for practicability, following ECCLSguidelines. Twenty-two analytes were tested and compared with the Olympus A U5000 analyser. A Hitachi 747 analyser was also included in this survey in order to obtain correlation data for ISE measurements.The imprecision data, expressed as median C...
متن کاملA systematic evaluation of the Olympus AU5061 as an effective replacement for the SMAC II analyser
متن کامل
Letter to the Editor: The effects of hyperlipidaemia, hyperbilirubinaemia and haemolysis on tests performed by the Olympus AU 5000 multiple analyser
Increasing amounts ofIntralipid (Kabivitrum), bilirubin (NBS standard 916) or haemolysate were added to a serum pool of 40 patients, as previously described [1]. Added Intralipid yielded samples with triglyceride levels of 0"8-6-3 g/l, added bilirubin yielded samples having total bilirubin levels of 4-325 mg/1 and added haemolysate yielded samples with haemoglobin concentrations of 0-1"58 g/1. ...
متن کاملSynthesis of Au Nanoparticles by Thermal, Sonochemical and Electrochemical Methods: Optimization and Characterization
The present study concentrates on the synthesis of Au nanoparticles (AuNPs) using aqueous solution of Polyvinylpyrrolidone (PVP) and tetrachloroaurate by different methods as thermal, sonochemical and electrochemical reduction. The PVP has been used as a reducing agent and acts as a stabilizer for Au nano particles that obtained as principal product. In all synthesis procedures, the active radi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 13 شماره
صفحات -
تاریخ انتشار 1991