History of isothermic dialysis.

نویسنده

  • Hans-Dietrich Polaschegg
چکیده

History of isothermic dialysis Sir, The historical review of Francesco Pizzarelli [1] on isothermic dialysis is a valuable review of the physiological and clinical relevant thermal processes during dialysis. The historical part of it is, however, incomplete and misleading. Isothermic dialysis was made available by the BTM (blood temperature monitor) of Fresenius. The physics of thermal energy balance and reasoning on physiology was the basis for the development of this device, which started in 1983. When I became aware of the pioneering paper of Maggiore et al. [2] it was obvious to me that thermal energy but not dialysate temperature was the relevant parameter for the effects reported by these authors. At this time, Fresenius was a small German company without a marketing department. Decisions on development projects were proposed by research and development (R&D) and approved by the division manager. I was head of R&D for medical devices at Fresenius and proposed the development of the BTM, based on the physiological hypothesis that body temperature should be kept constant during dialysis. The results of laboratory and clinical tests were summarized in a patent application filed on 30 October 1986 [3] (US Patent 4894164 is an English version of this patent). This patent describes all the essentials of thermal energy balancing and isothermal dialysis including temperature drops in the extracorporeal circuit, measurement of the thermal energy balance, control of body temperature or alternatively control of energy removed. It also points out that energy neutral operation is not sufficient for keeping the body temperature constant. Curves of thermal energy balance under constant dialysate temperature condition, and alternatively under body temperature control, were published together with the physical basis and the physiological background of the BTM in a chapter of a popular textbook [4]. The same chapter in the latest edition of this book [5] also contains a physiological model of thermal control in dialysis, as well as a quantitative calculation of thermal cooling in haemodiafiltration and haemofiltration. The papers of the authors mentioned by Pizarelli corroborate the concept of the BTM and contribute to the understanding of the importance of thermal balance in haemodialysis, but they were only possible because a commercial device was available that was developed without the contribution of these authors. Discussion Scientific contributions in journals (which include novel methods and devices) are usually quoted using the names of the authors. Industrial devices are usually quoted by the …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Control of core temperature and blood pressure stability during hemodialysis.

BACKGROUND AND OBJECTIVES Cool dialysate may ameliorate intradialytic hypotension (IDH). It is not known whether it is sufficient to prevent an increase in core temperature (CT) during hemodialysis (HD) or whether a mild decline in CT would yield superior results. The aim of this study was to compare both approaches with regard to IDH. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Fourteen HD...

متن کامل

Investigation of coronary artery calcification and stenosis by coronary angiography (CAG) in haemodialysis patients.

consistently shown the benefits of cool dialysis in the prevention of IDH. Certainly, prescription of isothermic treatments controlled by the blood temperature feedback module (BTM) is not only appealing from a theoretical point of view, but was also found to be efficacious for the prevention of IDH in the randomized crossover trial by Maggiore et al. [8]. However, a practical drawback for the ...

متن کامل

Effect of Isovolemic, Isothermic Hemodialysis on Cerebral Perfusion and Vascular Stiffness Using Contrast Computed Tomography and Pulse Wave Velocity

BACKGROUND Patients undergoing hemodialysis treatment have a six-fold increased risk for stroke relative to the general population. However, the effect of hemodialysis on cerebral blood flow is poorly studied and confounding factors like blood pressure and ultrafiltration as well as temperature changes have rarely been accounted for. The aim of our study was to use state-of-the-art technology t...

متن کامل

Isothermic Surfaces and Hopf Cylinders

Based on the work of Pinkall, characterizations of spherical curves are given whose corresponding Hopf cylinders are isothermic surfaces in the threedimensional sphere. Comparing these characterizations with results of Langer and Singer about elastic spherical curves we determine all isothermic Willmore Hopf tori.

متن کامل

Computational complexity of isothermic DNA sequencing by hybridization

In the paper, the computational complexity of several variants of the problem of isothermic DNA sequencing by hybridization, is analyzed. The isothermic sequencing is a recent method, in which isothermic oligonucleotide libraries are used during the hybridization with an unknown DNA fragment. The variants of the isothermic DNA sequencing problem with errors in the hybridization data, negative o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2007