Report of a nationwide survey on actual administered radioactivities of radiopharmaceuticals for diagnostic reference levels in Japan
نویسندگان
چکیده
OBJECTIVE The optimization of medical exposure is one of the major issues regarding radiation protection in the world, and The International Committee of Radiological Protection and the International Atomic Energy Agency recommend establishing diagnostic reference levels (DRLs) as tools for dose optimization. Therefore, the development of DRLs based on the latest survey has been required for nuclear medicine-related societies and organizations. This prompted us to conduct a nationwide survey on the actual administered radioactivity to adults for the purpose of developing DRLs in nuclear medicine. METHODS A nationwide survey was conducted from November 25, 2014 to January 16, 2015. The questionnaire was sent to all of the 1249 nuclear medicine facilities in Japan, and the responses were collected on a website using an answered form. RESULTS Responses were obtained from 516 facilities, for a response rate of 41 %. 75th percentile of (99m)Tc-MDP and (99m)Tc-HMDP: bone scintigraphy, (99m)Tc-HM-PAO, (99m)Tc-ECD and (123)I-IMP: cerebral blood flow scintigraphy, (99m)Tc-Tetrofosmin, (99m)Tc-MIBI and (201)Tl-Cl; myocardial perfusion scintigraphy and (18)F-FDG: oncology PET (in-house-produced or delivery) in representative diagnostic nuclear medicine scans were 932, 937, 763, 775, 200, 831, 818, 180, 235 and 252, respectively. More than 90 % of the facilities were within the range of 50 % from the median of these survey results in representative diagnostic nuclear medicine facilities in Japan. Responses of the administered radioactivities recommended by the package insert, texts and guidelines such as 740 MBq ((99m)Tc-MDP and (99m)Tc-HMDP: bone scintigraphy), 740 MBq ((99m)Tc-ECD and (99m)Tc-HM-PAO: cerebral blood flow scintigraphy) and 740 MBq ((99m)Tc-Tetrofosmin and (99m)Tc-MIBI: myocardial perfusion scintigraphy), etc. were numerous. The administered activity of many radiopharmaceuticals of bone scintigraphy ((99m)Tc-MDP and (99m)Tc-HMDP), cerebral blood flow scintigraphy ((99m)Tc-HM-PAO) and myocardial perfusion scintigraphy ((99m)Tc-Tetrofosmin and (99m)Tc-MIBI), etc. were within the range of the EU DRLs and almost none of the administered radioactivity in Japan exceeded the upper limit of SNMMI standard administered radioactivity. CONCLUSIONS This survey indicated that the administered radioactivity in diagnostic nuclear medicine in Japan had been in the convergence zone and nuclear medicine facilities in Japan show a strong tendency to adhere to the texts and guidelines. Furthermore, the administered radioactivities in Japan were within the range of variation of the EU and the SNMMI administered radioactivities.
منابع مشابه
The Status of Stress Myocardial Perfusion Imaging Using 99mTc Pharmaceuticals in Japan: Results from a Nationwide Survey
Objective(s): To appropriately use one-day myocardial perfusion imaging (MPI) with 99mTc radiopharmaceuticals (i.e. to avoid shine-through artifacts), injection doses need to be optimized and dose ratios between the 1st and 2nd scans should be maintained at ≥ 3. However, the current state of practice in Japan is unclear. Thus, the aim of this study was to clarify the details of MPI protocols us...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملThe need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography
Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...
متن کاملDetection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey
Objective(s): The aim of this study was to analyze detection rates and effectiveness of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests ...
متن کاملLocal Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...
متن کامل