Understanding the Complexity of Porous Graphitic Carbon (PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions Overcomes Loss of Retention and Reduces Variability

نویسندگان

  • Tashinga E. Bapiro
  • Frances M. Richards
  • Duncan I. Jodrell
چکیده

Porous graphitic carbon (PGC) is an important tool in a chromatographer's armory that retains polar compounds with mass spectrometry (MS)-compatible solvents. However, its applicability is severely limited by an unpredictable loss of retention, which can be attributed to contamination. The solutions offered fail to restore the original retention and our observations of retention time shifts of gemcitabine/metabolites on PGC are not consistent with contamination. The mobile phase affects the ionization state of analytes and the polarizable PGC surface that influences the strength of dispersive forces governing retention on the stationary phase. We hypothesized that failure to maintain the same PGC surface before and after running a gradient is a cause of the observed retention loss/variability on PGC. Herein, we optimize the choice of mobile phase solvent in a gradient program with three parts: a preparatory phase, which allows binding of analytes to column; an elution phase, which gives the required separation/peak shape; and a maintenance phase, to preserve the required retention capacity. Via liquid chromatography/tandem mass spectrometry (LC-MS/MS) analysis of gemcitabine and its metabolites extracted from tumor tissue, we demonstrate reproducible chromatography on three PGC columns of different ages. This approach simplifies use of the PGC to the same level as that of a C-18 column, removes the need for column regeneration, and minimizes run times, thus allowing PGC columns to be used to their full potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the structure of biomass-derived non-graphitising mesoporous carbons by electron energy loss spectroscopy in the transmission electron microscope and X-ray photoelectron spectroscopy

We have investigated the microstructure and bonding of two biomass-based porous carbon chromatographic stationary phase materials (alginic acid-derived Starbon ® and calcium alginate-derived mesoporous carbon spheres (AMCS)) and a commercial porous graphitic carbon (PGC), using high resolution transmission electron microscopy, electron energy loss spectroscopy (EELS), N2 porosimetry and X-ray p...

متن کامل

Croatica Chemica Acta

The retention time of 23 barbituric acid derivatives was determined on an narrow-bore porous graphitized carbon (PGC) column employing water-dioxane mixtures as mobile phases. The retention factor (k), theoretical plate number (N), and asymmetry factor (AF) were computed for each analyte in each mobile phase. Quantitative structure-retention relationship (QSRR) calculations using stepwise regre...

متن کامل

Simultaneous effect of organic modifier and physicochemical parameters of barbiturates on their retention on a narrow-bore PGC column.

The retention time of 22 barbituric acid derivatives was measured on a narrow-bore porous graphitized carbon (PGC) column using water-dioxane mixtures as mobile phases. The capacity factor (k), theoretical plate number (N), and asymmetry factor (AF) were calculated for each solute in each mobile phase. The relationships between chromatographic characteristics and physicochemical parameters of s...

متن کامل

Development of Techniques and Methods for Drug Analysis by Packed Capillary Liquid Chromatography with Octadecylbonded Silica and Porous Graphitic Carbon Columns

Koivisto, P. 2001. Development of Techniques and Methods for Drug Analysis by Packed Capillary Liquid Chromatography with Octadecylbonded Silica and Porous Graphitic Carbon Columns. Acta Universitatis Upsaliensis. Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 599. 45 pp. Uppsala. ISBN 91-554-4920-4. Packed capillary liquid chromatography in combinat...

متن کامل

Analysis of carbohydrates in Lupinus albus stems on imposition of water deficit, using porous graphitic carbon liquid chromatography-electrospray ionization mass spectrometry.

This work reports the development and application of a negative ion mode online LC-ESI-MS method for studying the effect of water deficit on the carbohydrate content of Lupinus albus stems, using a porous graphitic carbon (PGC) stationary phase and an ion trap mass spectrometer. Using this method, separation and detection of several water soluble carbohydrates, ranging from mono-, di-, and olig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 88  شماره 

صفحات  -

تاریخ انتشار 2016