Nonlinear Static Procedure for Fragility Curve Development
نویسندگان
چکیده
This study examines the fragility curves of a bridge by two different analytical approaches; one utilizes the time-history analysis and the other uses the capacity spectrum method. The latter approach is one of the simplified nonlinear static procedures recently developed for buildings. In this respect, a sample of 10 nominally identical but statistically different bridges and 80 ground-motion time histories are considered to account for the uncertainties related to the structural capacity and ground motion, respectively. The comparison of fragility curves by the nonlinear static procedure with those by time-history analysis indicates that the agreement is excellent for the state of at least minor damage, but not as good for the state of major damage where nonlinear effects clearly play a crucial role. Overall, however, the agreement is adequate even in the state of major damage considering the large number of typical assumptions under which the analyses of fragility characteristics are performed.
منابع مشابه
Assessment of Structure-Specific Fragility Curves for Soft Storey Buildings Implementing IDA and SPO Approaches
Soft storey building is popular due to the functional and aesthetic purpose, despite its weakness in resisting seismic excitation. Nonlinear Static (Pushover) Analysis (POA) is a time saving and simple assessment procedure prosposed in Eurocode 8 (EC8). However, its reliability in designing structure still remains a question. At the first stage, seismic performance of several building models us...
متن کاملFragility Curves for Reinforced Concrete Frames with Lap-Spliced Columns
Placing column lap-splice in the locations of possible nonlinear deformation may adversely affect the structures response to strong ground motions. Localization of damage in splice zone may change the structural response and prevent the load redistribution and development of a uniform pattern of nonlinear excursions among the various members. Validated by existing laboratory experiments, this s...
متن کاملEvaluation of Nonlinear Dynamic Response of Rigid and Semi-Rigid Steel Frames under Far-Field Earthquake Records
The purpose of this research was to evaluate the nonlinear dynamic response of rigid and semi-rigid steel frames under Far-Fault Earthquake Records. Accordingly, the fragility curve of the moment frames with rigid and semi-rigid connections was determined. Considering the analytical knowledge of structures in the past, the analysis and design of steel frames based on the assumptions of rigid or...
متن کاملDevelopment of Fragility and Reliability Curves and Seismic Vulnerability Evaluation of Talehzang Concrete Bridge
Bridges are potentially one of the most seismically vulnerable structures in the highway system during earthquake 
 
events. It is known that the seismic performance of transportation systems plays a key role in the post-earthquake emergency management. Hence, it is necessary to evaluate both physical and functional aspects of bridge structures. The physical aspects of the seismic perform...
متن کاملAn Energy Based Adaptive Pushover Analysis for Nonlinear Static Procedures
Nonlinear static procedure (NSP) is a common technique to predict seismic demands on various building structures by subjecting a monotonically increasing horizontal loading (pushover) to the structure. Therefore, the pushover analysis is an important part of each NSP. Accordingly, the current paper aims at investigating the efficiencyof various algorithms of lateral load patterns applied to the...