UDECON: deconvolution optimization software for restoring high-resolution records from pass-through paleomagnetic measurements
نویسندگان
چکیده
The rapid accumulation of continuous paleomagnetic and rock magnetic records acquired from pass-through measurements on superconducting rock magnetometers (SRM) has greatly contributed to our understanding of the paleomagnetic field and paleo-environment. Pass-through measurements are inevitably smoothed and altered by the convolution effect of SRM sensor response, and deconvolution is needed to restore high-resolution paleomagnetic and environmental signals. Although various deconvolution algorithms have been developed, the lack of easy-to-use software has hindered the practical application of deconvolution. Here, we present standalone graphical software UDECON as a convenient tool to perform optimized deconvolution for pass-through paleomagnetic measurements using the algorithm recently developed by Oda and Xuan (Geochem Geophys Geosyst 15:3907–3924, 2014). With the preparation of a format file, UDECON can directly read pass-through paleomagnetic measurement files collected at different laboratories. After the SRM sensor response is determined and loaded to the software, optimized deconvolution can be conducted using two different approaches (i.e., "Grid search" and "Simplex method") with adjustable initial values or ranges for smoothness, corrections of sample length, and shifts in measurement position. UDECON provides a suite of tools to view conveniently and check various types of original measurement and deconvolution data. Multiple steps of measurement and/or deconvolution data can be compared simultaneously to check the consistency and to guide further deconvolution optimization. Deconvolved data together with the loaded original measurement and SRM sensor response data can be saved and reloaded for further treatment in UDECON. Users can also export the optimized deconvolution data to a text file for analysis in other software.
منابع مشابه
Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملHigh-resolution magnetic analysis of sediment cores: Strengths, limitations and strategies for maximizing the value of long-core magnetic data
Narrow-access long-core cryogenic magnetometers enable measurement of a range of magnetic parameters at a speed and resolution that cannot be matched by other techniques. Despite the revolutionary impact that these instruments have had on paleomagnetic and environmental magnetic investigations, some fundamental constraints limit their usefulness. First, the pick-up coils have different response...
متن کاملHolocene Paleomagnetic Secular Variation Records from the Western Equatorial Pacific Ocean
We have carried out detailed rock magnetic and paleomagnetic studies on a suite of four deep-sea sediment cores from Indonesia and the Philippine Islands, which form a transect from 6.3°N to 10.6°S. The cores have average sediment accumulation rates of 35-65 cm/kyr that all yield high-resolution paleomagnetic secular variation (PSV) records. The PSV records contain 44 correlatable inclination a...
متن کامل34. Magnetostratigraphy of Upper Cenozoic Sediments from Leg 145, North Pacific Ocean
Paleomagnetic measurements were performed on whole cores and discrete samples from approximately 4 km of sediment recovered during Leg 145 of the Ocean Drilling Program. The obtained magnetic polarity sequences enabled the establishment of a chronostratigraphic framework from the middle Miocene (about 18.3 Ma) to the present. The quality of the magnetic record is related directly to the sedimen...
متن کاملDeconRNASeq: a statistical framework for deconvolution of heterogeneous tissue samples based on mRNA-Seq data
SUMMARY For heterogeneous tissues, measurements of gene expression through mRNA-Seq data are confounded by relative proportions of cell types involved. In this note, we introduce an efficient pipeline: DeconRNASeq, an R package for deconvolution of heterogeneous tissues based on mRNA-Seq data. It adopts a globally optimized non-negative decomposition algorithm through quadratic programming for ...
متن کامل