Author response: retinal thickness measurement in OCT.

نویسندگان

  • John F Payne
  • Beau B Bruce
  • Steven Yeh
چکیده

which is the case only if the reference planes do not change position during the time interval or if the difference between the two planes is negligibly small. It may be that for some diseases, such as diabetic retinopathy and other retinal vascular diseases, that only the inner retinal layer moves and the reference planes (e.g., the tips of the outer segment or the first bright RPE reflection) do not move, in which case the linear difference between measurements will be machine invariant [as (b2 b1) is zero and (a2 a1) is zero]. However, in florid cystoid macular edema, where the photoreceptor layer itself detaches from the RPE or where the position of the RPE layer moves (e.g., RPE detachment reducing after intravitreal ranibizumab), then the linear difference between different machines will not be invariant. In summary, retinal thicknesses derived from OCT measurements are interval data. There is no natural zero, and the numerical value of the thickness always depends on the choice of reference plane. The ratio of two thickness measurements made at different time intervals and the logarithm of this ratio varies from machine to machine. The linear difference between thicknesses at these different times may be machine independent, but only if the position of the reference plane remains unchanged with the passage of time. We therefore warn the retinal community against performing studies in which different OCT machines are used and ratios of thicknesses are calculated and treated as comparable. Such comparisons would introduce errors in the data that are collected. We hope that our analysis explains this concern. Sahar Parvizi Nigel P. Davies

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Baseline subfoveal choroidal thickness as an indicator for bevacizumab outcomes in central retinal vein occlusion

Background: Retinal vein occlusions are one of the most common form of retinal vascular disorders and could lead to vision loss due to macular edema, macular ischemia and sequelae from neovascularization. Anti-venous endothelial growth factor (anti-VEGF) treatment is the choice strategy of treatment for patients with macular edema secondary to central retinal vein occlusion (CRVO). There is an ...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Evaluation of Normal Choroidal Thickness in Rasht Using SD-OCT EDI Imaging

Purpose: To measure choroidal thickness in normal subjects, using optical coherent tomography (OCT) in Rasht. Methods: Normal subjects older than 20 years, living in Rasht, were selected through systematic random sampling by using the city telephone directory. The subjects underwent comprehensive eye examinations for inclusion in the study. Then, choroidal thickness was measured in both eyes by...

متن کامل

Optical coherence tomography measurements and analysis methods in optical coherence tomography studies of diabetic macular edema.

OBJECTIVE To evaluate optical coherence tomography (OCT) measurements and methods of analysis of OCT data in studies of diabetic macular edema (DME). DESIGN Associations of pairs of OCT variables and results of 3 analysis methods using data from 2 studies of DME. PARTICIPANTS Two hundred sixty-three subjects from a study of modified Early Treatment of Diabetic Retinopathy Study (mETDRS) ver...

متن کامل

Relationship of Retinal Nerve Fibers Layer Thickness with Mild Cognitive Impairment and Alzheimer's Dementia

Background and Objective: In this study, the thickness of the retinal nerve fibers layer(RNFL) was compared among patients with mild cognitive impairment, Alzheimer's dementia, and healthy individuals (controls) using Optical Coherence Tomography (OCT) device. Materials and Methods: This case-control study was conducted on 30 patients diagnosed with mild cognitive impairment and 31 healthy sub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 2012