We propose a new body sensor for extracting the respiration rate based on the amplitude changes in the body surface potential differences between two proximal body electrodes. The sensor could be designed as a plaster-like reusable unit that can be easily fixed onto the surface of the body. It could be equipped either with a sufficiently large memory for storing the measured data or with a low-power radio system that can transmit the measured data to a gateway for further processing. We explore the influence of the sensor’s position on the quality of the extracted results using multi-channel ECG measurements and considering all the pairs of two neighboring electrodes as potential respiration-rate sensors. The analysis of the clinical measurements, which also include reference thermistor-based respiration signals, shows that the proposed approach is a viable option for monitoring the respiration frequency and for a rough classification of breathing types. The obtained results were evaluated on a wireless prototype of a respiration body sensor. We indicate the best positions for the respiration body sensor and prove that a single sensor for body surface potential difference on proximal skin electrodes can be used for combined measurements of respiratory and cardiac activities.
منابع مشابه
Two Proximal Skin Electrodes—A Body Sensor for Respiration Rate
We propose a new body sensor for extracting the respiration rate based on the amplitude changes in the body surface potential differences between two proximal body electrodes. The sensor could be designed as a plaster-like reusable unit that can be easily fixed onto the surface of the body. It could be equipped either with a sufficiently large memory for storing the measured data or with a low-...
متن کاملWearable Contactless Respiration Sensor Based on Multi-Material Fibers Integrated into Textile
In this paper, we report on a novel sensor for the contactless monitoring of the respiration rate, made from multi-material fibers arranged in the form of spiral antenna (2.45 GHz central frequency). High flexibility of the used composite metal-glass-polymer fibers permits their integration into a cotton t-shirt without compromising comfort or restricting movement of the user. At the same time,...
متن کاملWireless Bio- medical Sensor Network for Heartbeat and Respiration Detection
A wireless bio-medicalr sensor Network was designed to detect a human heartbeat and respiration signals without direct skin contact. In order to design a wireless bio-medical sensor quantitatively, the signal to-noise ratio (SNR) in the baseband output of a sensor should be calculated. Therefore, we analyzed the SNR of the wireless biomedical sensor, considering the signal power attenuation in ...
متن کاملPitfalls in respiratory monitoring of premature infants during kangaroo care.
The reliability of respiratory monitoring, using either chest or back electrodes, was studied in 13 preterm infants during kangaroo care (infant-parent skin to skin contact). In three out of four infants with chest electrodes both infant and parental respiration were clearly visible on pneumograms. In these infants apnoeic pauses were not registered because parental respiration was recorded as ...
متن کاملRegional differences in sweat rate response of steers to short-term heat stress.
Six Angus steers (319 +/- 8.5 kg) were assigned to one of two groups (hot or cold exposure) of three steers each, and placed into two environmental chambers initially maintained at 16.5-18.8 degrees C air temperature (Ta). Cold chamber Ta was lowered to 8.4 degrees C, while Ta within the hot chamber was increased to 32.7 degrees C over a 24-h time period. Measurements included respiration rate,...