Paramagnetic shimming for high- eld MRI
نویسندگان
چکیده
The diamagnetism of biological tissues reduces the homogeneity of the magnetic field and may limit the number of samples in multi-sample gradient-recalled echo (GRE) experiments. This study aims to 1) evaluate the magnetic field distortions and signal loss artifacts in GRE images of proximal water samples, and 2) develop a passive shimming device to overcome this limitation. The magnetic field distribution produced by a diamagnetic H2O sphere and a paramagnetic CuSO4 disk in a secondary phantom were mapped using GRE experiments and the phase reference method, and compared to the corresponding magnetostatics models. The water sphere produced a pronounced signal loss artifact in amplitude images. This artifact was significantly reduced when the paramagnetic disk was placed symmetrically between the water sphere and the secondary spherical phantom. The present study suggests that the use of paramagnetic shimming devices can help to minimize susceptibilityrelated MRI signal losses and to increase the number of samples in multi-sample MRI experiments. The volume susceptibility and the shape of paramagnetic shimming devices could be optimized for particular setups and samples accordingly.
منابع مشابه
Paramagnetic shimming for wide-range variable-field NMR.
We propose a new passive shimming strategy for variable-field NMR experiments, in which the magnetic field produced by paramagnetic shim pieces placed inside the magnet bore compensates the inhomogeneity of a variable-field magnet for a wide range of magnet currents. Paramagnetic shimming is demonstrated in (7)Li, (87)Rb, and (45)Sc NMR of a liquid solution sample in magnetic fields of 3.4, 4.0...
متن کاملStudy on Shimming Method for Open Perma- Nent Magnet of Mri
The shimming method used for producing high field homogeneity of the open permanent main magnet for magnetic resonance imaging (MRI) is researched in this paper. The central shimming method based on integer programming is proposed, which fulfills the combination of optimal theory and the practical manual shimming. The formulation of shimming is solved by using Lingo software and the numerical a...
متن کاملMRS Shimming: An Important Point Which Should not be Ignored
Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...
متن کاملExtended RF shimming: Sequence‐level parallel transmission optimization applied to steady‐state free precession MRI of the heart
Cardiac magnetic resonance imaging (MRI) at high field presents challenges because of the high specific absorption rate and significant transmit field (B1+ ) inhomogeneities. Parallel transmission MRI offers the ability to correct for both issues at the level of individual radiofrequency (RF) pulses, but must operate within strict hardware and safety constraints. The constraints are themselves ...