Beam Lifetime of the Pohang Light Source
نویسندگان
چکیده
Like other third generation light sources, main contributions to the be am lifetime of the Pohang Light Source come from the beam-gas scattering and the Touschek effect. The beam-gas scattering lifetime is measured with extremely low stored current in the long train of bunches. By investigating the vertical gap dependence of the beam-gas scattering lifetime, it i possible to decompose the beam-gas scattering lifetime to the elastic and inelastic parts. On the other hand, the Touschek lifetime is analyzed using the graph of the measured beam lifetime as a function of time. It i s used that the rate of change of the pure Touschek lifetime is exactly 1. The deviation from 1 is caused by the beam-gas scattering effect and the radiative electron beam polarization. By analyzing the graph, it is possible to estimate the beam-gas scattering lifetime and the polarization contribution to the beam lifetime.
منابع مشابه
Operational Status of the Pohang Light Source*
Since 1995, the Pohang Light Source has been serving as the unique synchrotron radiation facility in Korea. In 2001, beam time scheduled for users was 4,056 hours. The actual beam time supplied to users was 3,806 hours recording a beam availability of 93.8%. Number of beamline experiments was 292, carried out by 1,087 users. On the technical side, the most important issue in PLS operation is th...
متن کاملStatus of Pohang Light Source
The Pohang Light Source (PLS) is a national users’ facility for basic and applied science research using synchrotron radiation. It consists of a 2-GeV linac as a full-energy injector and a low-emittance, thirdgeneration storage ring. It has been serving users since September of 1995. The beamlines have been increased from two to eight units as the increased number of users. The first undulator,...
متن کاملMeasurement of Beam Characteristics of Pls Linac*
The PLS (Pohang Light Source) linac has been operated routinely as the injection linac for PLS, a thirdgeneration synchrotron light source. The transverse electron beam emittance was measured at the preinjector end of the PLS linac, where the beam energy is about 100 MeV. The emittance was measured using a quadrupole magnet and a fluorescent target. We used a progressive scan CCD camera with an...
متن کاملAnalysis and control of the photon beam position at PLS-II
At third-generation light sources, the photon beam position stability is a critical issue for user experiments. In general, photon beam position monitors are developed to detect the real photon beam position, and the position is controlled by a feedback system in order to maintain the reference photon beam position. At Pohang Light Source II, a photon beam position stability of less than 1 µm r...
متن کاملPulsed Neutron Source Using 100-mev Electron Linac at Pohang Accelerator Laboratory
The Pohang Accelerator Laboratory operates an electron linac for a pulsed neutron source as one of the long-term nuclear R&D programs at the Korea Atomic Energy Research Institute. The designed beam parameters are as follows; The nominal beam energy is 100 MeV, the maximum beam power is 10 kW, and the beam current is varied from 300 mA to 5A depends on the pulse repetition rate. The linac has t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001