System for dose audit for external radiation therapy based on EPR dosimetry with Lithium Formate

نویسنده

  • Sara Olsson
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lithium formate EPR dosimetry for accurate measurements of absorbed dose in radiotherapy

Lithium formate has shown to be a material with properties suitable for electron paramagnetic resonance (EPR) dosimetry, among them up to 7 times higher sensitivity compared to alanine, which is a well-established EPR detector material for dose determinations in radiotherapy. The aim of this thesis was to further investigate the properties of lithium formate and develop the dosimetry system tow...

متن کامل

A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry.

The aim of this work was to develop and test a remote end-to-end audit system using lithium formate EPR dosimeters. Four clinics were included in a pilot study, absorbed doses determined in the PTV agreed with TPS calculated doses within ±5% for 3D-CRT and ±7% (k=1) for IMRT/VMAT dose plans.

متن کامل

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

Gel dosimetry: The effect of gold nanoparticles on the dose enhancement in the external radiation therapy

Background: Normoxic type MAGICA gel dosimeters are established for dose quantification in three dimensions for radiotherapy. Objective(s): The ability of MAGICA polymer gel was assessed by experimental measurements method for studying the effect of gold nanoparticles (GNPs) in dose enhancement under the external 18MV radiotherapy practices. <...

متن کامل

Photon Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017

Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...