چکیده

The aim of this work was to verify the existence of correlation between Raman spectroscopy readings of phosphate apatite (~960 cm-1), fluoridated apatite (~575 cm-1) and organic matrix (~1450 cm-1) levels and Diagnodent® readings at different stages of dental caries in extracted human teeth. The mean peak value of fluorescence in the carious area was recorded and teeth were divided in enamel caries, dentin caries and sound dental structure. After fluorescence readings, Raman spectroscopy was carried out on the same sites. The results showed significant difference (ANOVA, p<0.05) between the fluorescence readings for enamel (16.4 ± 2.3) and dentin (57.6 ± 23.7) on carious teeth. Raman peaks of enamel and dentin revealed that ~575 and ~960 cm-1 peaks were more intense in enamel caries. There was significant negative correlation (p<0.05) between the ~575 and ~960 cm-1 peaks and dentin caries. It may be concluded that the higher the fluorescence detected by Diagnodent the lower the peaks of phosphate apatite and fluoridated apatite. As the early diagnosis of caries is directly related to the identification of changes in the inorganic tooth components, Raman spectroscopy was more sensitive to variations of these components than Diagnodent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Diagnodent Accuracy in Detecting Approximal Caries in Primary Molars

Introduction: Detection of caries lesions on approximal surfaces of posterior teeth is difficult, since wide contact points hamper direct visual inspection. Due to the importance of the early detection of dental caries, the aim of this study is to compare the performance of different methods (visual, bitewing radiography and DIAGNOdent) in detecting approximal caries in primary molars. Methods:...

متن کامل

A comparative evaluation of DIAGNOdent and caries detector dye in detection of residual caries in prepared cavities.

AIM The objective of this study was to determine the association between DIAGNOdent laser and caries detector dye in detection of the remaining caries in restorative cavities. MATERIALS AND METHODS The sample consisted of 100 cavities prepared in patients referring to the Department of Restorative Dentistry of Mashhad Dental School. After confirming caries absence by tactile examination, the ...

متن کامل

Optical Spectroscopic Methods to Discriminate in-Vitro Hodgkin Cancerous and Normal Tissues

Simultaneous laser induced- breakdown spectroscopy (LIBS) and acoustic response techniques as well as Laser induced fluorescence (LIF) are applied to investigate the abnormal lymph tissues due to Hodgkin disease. The spectral shift in the emissive fluorescence of the cancerous tissues has been observed respect to the normal ones. Regarding LIBS, the concentrations of Ca and Na trace elements ha...

متن کامل

Cavity-enhanced laser spectroscopic studies of vibrational overtones of acetylene

This thesis contains five experimental spectroscopic studies that probe the vibration–rotation energy level structure of acetylene and some of its isotopologues. The emphasis is on the development of laser spectroscopic methods for high-resolution molecular spectroscopy. Three of the experiments use cavity ringdown spectroscopy. One is a standard setup that employs a non-frequency stabilised co...

متن کامل

Diagnodent® and the caveats of caries diagnosis by laser fluorescence

The Diagnodent device is based on principles of caries detection by laser fluorescence which were developed in Sweden in the mid-1980s. Since that time, several lasers have been employed for caries detection (such as the argon, carbon dioxide, and excimer lasers). These systems are however more complex to use and more expensive than the visible red diode laser system upon which Diagnodent® is b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2013