Thermogravimetric Study of Oxide Spallation for Chromium-Rich Cast Cobalt-Based and Iron-Based Alloys Oxidized at High Temperature

نویسنده

  • Patrice Berthod
چکیده

During temperature cycles, metallic alloys for high temperature applications are usually oxidized with formation of an external protective oxide scale, but they loose it during the cooling. This problem of oxide spallation can be studied by specific tests of cyclic oxidation but first indications can be provided by analyzing the cooling parts of thermogravimetry curves. This possibility was studied in this work for simple {Co or Fe} – 30 wt.% Cr alloys containing between 0 and 0.8 wt.% of carbon, and for two of these alloys after addition of about 5 wt.% of tantalum. These alloys, elaborated by foundry process, were exposed to oxidation at 1000, 1100 or 1200°C for 50 hours, with recording of their mass gain during heating, isothermal dwell and cooling. The analysis of the cooling part of the thermogravimetry files allowed specifying several data characterizing the spallation of the external oxide, such as the temperature at which the phenomenon begins and the rate with which the mass decreases because of the loss of oxide. Metallographic data about oxidation and spallation were obtained by examination of cross-sections of the oxidized samples. Oxide spallation, characterized by its beginning’s temperature and its corresponding mass loss rate, was obviously more severe for the cobalt alloys than for the iron ones, for the carbon-free alloys than for carbides-containing ones and for tantalum-containing alloys than for the tantalum-free ones. Most of these effects were explained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oxidation Start Detection on Heating Parts of Thermogravimetry Curves for High Temperature Alloys Based on Nickel, Cobalt or Iron

The heating parts of thermogravimetry curves performed for cast alloys in air at high temperatures were analysed, after correction from the effects of air buoyancy variation, to characterize the transient oxidation before reaching the targeted temperature for the isothermal stage usually applied thereafter. This was done here for three binary M-30Cr alloys, six ternary M-30Cr-0.4 and 0.8%C allo...

متن کامل

Pretreatment of Gray Cast Iron for Hard Chromium Electroplating (RESEARCH NOTES)

From the standpoint of processing, hard chromium layer plate may be applied to steels, cast iron, aluminum and nickel base alloys. Cast iron can be plated provided that the surface is capable of conducting the required current and is reasonably free of voids, pits, gross silicate inclusions, and massive segregation. There are many difficulties arising from graphite phase and deposition of hydro...

متن کامل

New Creep-Resistant Cast Alloys with Improved Oxidation Resistance in Water Vapor at 650–800°C

Cast stainless steel CF8C-Plus (19wt%Cr/12%Ni) has excellent creep properties, but limited oxidation resistance above 700°C in environments containing H2O. One strategy to improve the alloy oxidation performance is to increase the Cr and Ni concentration. Two new alloys, with, respectively, 21wt%Cr–15wt%Ni and 22wt%Cr–17.5wt%Ni were therefore developed and their long-term oxidation behaviors in...

متن کامل

Structural and Mechanical Characterization of Austempered Cu - Sn Ductile Iron Alloys

The effect of heat treatment and alloying elements of copper and tin on the microstructure and mechanical properties of austempered ductile cast iron alloys is investigated. The austenitizing temperature of 890°C, the isothermal transformation (austempering) temperatures of 285, 335 and 375°C, and austempering times of 15, 30, 75 and 150 minutes are studied. The alloying elements of copper and ...

متن کامل

Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints.

Most total knee replacement joints consist of a metal femoral component made from a cobalt-chromium- molybdenum (CoCrMo)-alloy and a tibial component with an ultrahigh molecular weight polyethylene (UHMWPE) bearing surface. Wear of the UHMWPE remains the primary disadvantage of these implants. The allergic potential ascribed to CoCrMo-alloys is a further concern. Other metallic alloys with and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009