Strain analysis of different diameter Morse taper implants under overloading compressive conditions.

نویسندگان

  • Carolina Guimarães Castro
  • Karla Zancopé
  • Crisnicaw Veríssimo
  • Carlos José Soares
  • Flávio Domingues das Neves
چکیده

The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10) according to their diameter as follows: 3.5 mm, 4.0 mm and 5.0 mm. Two-piece abutments were fixed into the implants, and the samples were subjected to compressive axial loading up to 1500 N of force. During the test, one strain gauge remained fixed to the cervical portion of each implant to measure the strain variation. The strain values were recorded at two different time points: at the maximum load (1500 N) and 60 seconds after load removal. To calculate the strain at the implant/abutment interface, a mathematical formula was applied. Data were analyzed using a one-way Anova and Tukey's test (α = 0.05). The 5.0 mm diameter implant showed a significantly lower strain (650.5 μS ± 170.0) than the 4.0 mm group (1170.2 μS ± 374.7) and the 3.5 mm group (1388.1 μS ± 326.6) (p < 0.001), regardless of the load presence. The strain values decreased by approximately 50% after removal of the load, regardless of the implant diameter. The 5.0 mm implant showed a significantly lower strain at the implant/abutment interface (943.4 μS ± 504.5) than the 4.0 mm group (1057.4 μS ± 681.3) and the 3.5 mm group (1159.6 μS ± 425.9) (p < 0.001). According to the results of this study, the diameter influenced the strain around the internal and external walls of the cervical region of Morse taper implants; all diameters demonstrated clinically acceptable values of strain.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heights in Morse-Taper Implants

of abutments with two different diameters and transmucosal heights used for cementretained implant-supported prostheses in Morse-taper implants. Forty Morse-taper implants were divided into four groups with different abutment sizes for cement-retained prostheses in order to perform the compressive test. The groups were divided by abutment diameter and transmucosal height as follows: Group 1: 4....

متن کامل

Mechanical analysis of conventional and small diameter conical implant abutments

PURPOSE The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment. MATERIALS AND METHODS Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their res...

متن کامل

Morse taper dental implants and platform switching: The new paradigm in oral implantology

The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: "Bone loss and platform switching," "bone loss and implant-abutment joint," "bone reso...

متن کامل

Influence of Connection Types and Implant Number on the Biomechanical Behavior of Mandibular Full-Arch Rehabilitation.

PURPOSE To evaluate the influence of different implant numbers and connection types on the biomechanical behavior of mandibular full-arch implant-supported rehabilitation. MATERIALS AND METHODS Computed tomography-based finite element models comprising a totally edentulous mandible and 3.8 × 13-mmdiameter implants, abutments, abutment screws, bar retaining screw, and bar were constructed. Dif...

متن کامل

Changes in the abutment-implant interface in Morse taper implant connections after mechanical cycling: a pilot study.

PURPOSE The aim of this study was to measure and compare, using scanning electron microscopy, the abutment-implant interface of a Morse taper system before and after cyclic loading. MATERIALS AND METHODS Four Morse cone implants and four solid abutments were used. These abutments had been machined to reduce the diameter of the part corresponding to the site of prosthesis cementation. They wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian oral research

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015