An Analysis of Gas Flow in the BaBar Drift Chamber

ثبت نشده
چکیده

An analysis based on the Green’s function for the diffusion equation indicates that the BaBar drift chamber could be purged of air down to 1 ppm in 8 hours with a purge gas velocity in the chamber of 0.043 cm/s, corresponding to one volume change every 2 hours. Anecdotal evidence from CLEO and ALEPH supports this claim. • It is proposed that the gas be fed into the chamber through 64 holes of 1/8′′ ID on the rear endplate at the lattice points of the electronics card-cage superstructure, and the gas be taken out through 64 corresponding holes in the front endplate. The average flow velocity in these tubes during purging would be 180 cm/s. • An analysis based on Landau’s jet solution to the Navier-Stokes equation indicates that the gas flow near the endplate between feed holes will be sufficient to insure good purging there. • Pressure drops in the gas feed system are the order of 0.1′′ of water. • The leakage of chamber gas out of (and air into) a feedthrough hole during a 5-minute wire repair would be only 20 cm on the rear endplate, and 130 cm on the front endplate. • The endplates will be surrounded by plena flushed with dry nitrogen at a flow rate of about one volume change per hour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The BaBar Drift Chamber

The central drift chamber for the BaBar detector at the PEP-II Bfactory at SLAC is a cylindrical chamber with a length of 280 cm and outer radius of 81 cm. It consists of 40 layers of small hexagonal cells arranged in 10 axial and stereo super-layers. In order to minimize multiple scattering, light materials are used for the mechanical structure, and the gas mixture is Helium based. The pulse-h...

متن کامل

BaBar drift chamber aging study

In order to obtain a reliable estimate of the lifetime of the BaBar drift chamber, a dedicated aging test chamber has been constructed. The working gas mixture is Helium/Isobutane (80/20). After accumulating up to 0.11C/cm charge dose the anode wire showed no appreciable signs of aging, but the field wires showed a small Malter effect. At 0.2C/cm the gas gain dropped B6–9% and the Malter effect...

متن کامل

Gas system Upgrade for the BaBar IFR detector at SLAC

A new gas distribution and monitoring system was installed as part of an upgrade of the forward endcap muon detection system (IFR) of the BaBar detector at SLAC. Over 300 gas circuits are controlled and monitored. The return gas flow is monitored by digital bubblers which use photo-gate electronics to count the bubbling rate. The rates are monitored in real time and recorded in a history databa...

متن کامل

Additives That Prevent Or Reverse Cathode Aging In Drift Chambers With Helium-Isobutane Gas

Noise and Malter breakdown have been studied at high rates in a test chamber having the same cell structure and gas as in the BaBar drift chamber. The chamber was first damaged by exposing it to a high source level at an elevated high voltage, until its operating current at normal voltages was only ~0.5nA/cm. Additives such as water or alcohol allowed the damaged chamber to operate at 25 nA/cm,...

متن کامل

Three Dimensional Stability Analysis of a Liquid Propellant Combustor

A theoretical study analyzing three-dimensional combustion acoustic instabilities in a liquid propellant rocket engine combustor has been conducted. A linear theory based on Crocco’s pressure sensitive time lag model is used. To apply this theory the combustor is divided into two main components, including the combustion chamber and the converging part of the nozzle. The assumption of concentra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002