Estimation of ocular volume from axial length.

نویسندگان

  • Manbir Nagra
  • Bernard Gilmartin
  • Nicola S Logan
چکیده

BACKGROUND/AIMS To determine which biometric parameters provide optimum predictive power for ocular volume. METHODS Sixty-seven adult subjects were scanned with a Siemens 3-T MRI scanner. Mean spherical error (MSE) (D) was measured with a Shin-Nippon autorefractor and a Zeiss IOLMaster used to measure (mm) axial length (AL), anterior chamber depth (ACD) and corneal radius (CR). Total ocular volume (TOV) was calculated from T2-weighted MRIs (voxel size 1.0 mm(3)) using an automatic voxel counting and shading algorithm. Each MR slice was subsequently edited manually in the axial, sagittal and coronal plane, the latter enabling location of the posterior pole of the crystalline lens and partitioning of TOV into anterior (AV) and posterior volume (PV) regions. RESULTS Mean values (±SD) for MSE (D), AL (mm), ACD (mm) and CR (mm) were -2.62±3.83, 24.51±1.47, 3.55±0.34 and 7.75±0.28, respectively. Mean values (±SD) for TOV, AV and PV (mm(3)) were 8168.21±1141.86, 1099.40±139.24 and 7068.82±1134.05, respectively. TOV showed significant correlation with MSE, AL, PV (all p<0.001), CR (p=0.043) and ACD (p=0.024). Bar CR, the correlations were shown to be wholly attributable to variation in PV. Multiple linear regression indicated that the combination of AL and CR provided optimum R(2) values of 79.4% for TOV. CONCLUSION Clinically useful estimations of ocular volume can be obtained from measurement of AL and CR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of Ramadan fasting on micronutrients and their relationship with the ocular axial length and anterior chamber depth

Introduction: The present study aimed to assess the effects of Ramadan fasting on micronutrients and their correlations with ocular biometry. Methods: This prospective study was conducted on 89 healthy volunteers (51 males and 38 females) with the mean of 34.98±9.10 years in Mashhad, Iran. Participants received complete ophthalmic and systemic examinations one week before and one week after the...

متن کامل

Estimation of axial curvature of anterior sclera: correlation between axial length and anterior scleral curvature as affected by angle kappa

BACKGROUND: Though the development and fitting of scleral contact lenses are expanding steadily, there is no simple method to provide scleral metrics for scleral contact lens fitting yet. The aim of this study was to establish formulae for estimation of the axial radius of curvature (ARC) of the anterior sclera using ocular biometric parameters that can be easily obtained with conventional de...

متن کامل

بررسی حجم و ابعاد کره چشم و عوامل مرتبط با ان با استفاده از MRI؛ کرمانشاه سال 1392

Abstract Background: Considering the importance of getting informed about the ocular volume and dimensions in treatment and surgical projects, and also the lack of information about the ocular volume in Iran. This investigation was performed in 1392 in Kermanshah. Materials and methods: This cross-sectional study carried out on 60 healthy individuals referred to imaging center at Imam Reza hosp...

متن کامل

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

Errors associated with IOLMaster biometry as a function of internal ocular dimensions.

PURPOSE To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). METHODS Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20mm to 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 98 12  شماره 

صفحات  -

تاریخ انتشار 2014