Selective enrichment of glycopeptides/phosphopeptides using porous titania microspheres.

نویسندگان

  • Jingyu Yan
  • Xiuling Li
  • Long Yu
  • Yu Jin
  • Xiuli Zhang
  • Xingya Xue
  • Yanxiong Ke
  • Xinmiao Liang
چکیده

Titanium dioxide (TiO(2)) microspheres synthesized by sol-gel method showed high affinity to glycopeptides and were successfully used for simultaneous enrichment of glycopeptides and phosphopeptides.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Titania coated magnetic mesoporous hollow silica microspheres: fabrication and application to selective enrichment of phosphopeptides.

Titania coated magnetic hollow mesoporous silica spheres with high surface area were created, which can be used in efficient and rapid capture of phosphopeptides from peptide mixtures.

متن کامل

Magnetic cellulose-TiO2 nanocomposite microspheres for highly selective enrichment of phosphopeptides.

Novel magnetic cellulose-TiO2 nanocomposite microspheres with high surface areas and magnetic susceptibility were fabricated, which exhibited remarkably selective enrichment of trace phosphopeptides from peptide mixtures.

متن کامل

Monodisperse REPO4 (RE = Yb, Gd, Y) hollow microspheres covered with nanothorns as affinity probes for selectively capturing and labeling phosphopeptides.

Rare-earth phosphate microspheres with unique structures were developed as affinity probes for the selective capture and tagging of phosphopeptides. Prickly REPO(4) (RE = Yb, Gd, Y) monodisperse microspheres, that have hollow structures, low densities, high specific surface areas, and large adsorptive capacities were prepared by an ion-exchange method. The elemental compositions and crystal str...

متن کامل

Facile synthesis of guanidyl-functionalized magnetic polymer microspheres for tunable and specific capture of global phosphopeptides or only multiphosphopeptides.

The highly selective and efficient capture of heterogeneous types of phosphopeptides is critical for comprehensive and in-depth phosphoproteome analysis, but it still remains a challenge since the lack of affinity material with large binding capacity and controllable specificity. Here, a new affinity material was prepared to improve the enrichment capacity and endue the tunable specificity by i...

متن کامل

Phosphopeptide-selective column-switching RP-HPLC with a titania precolumn.

A methodology of phosphopeptide-selective analysis coupled with column-switching HPLC utilizing titania as precolumn media is presented. Phosphopeptides were selectively enriched on titania packing within a protein/peptide mixture without any additional procedure, and analyzed by column-switching high-performance liquid chromatography. First, phospho-compounds were separated from complex mixtur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical communications

دوره 46 30  شماره 

صفحات  -

تاریخ انتشار 2010