Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.
نویسندگان
چکیده
We automated the Jendrassik-Grof method for measurement of bilirubin with the Greiner Selective Analyzer GSA II D. Comparison with the manual Jendrassik-Grof method showed a highly significant correlation coefficient of 0.994 for total and 0.980 for "direct" bilirubin measurement. The automated method showed good precision and was linear to 667 mu mol/L, the highest concentration tested. Addition of hemolysate caused a greater effect on the measurement of direct bilirubin than on total bilirubin. The inhibitory effect on measurement of total bilirubin, though small, was statistically significant at hemoglobin concentrations greater than 2 g/L. Comparison with the method involving diazotized 2,4-dichloroaniline showed the Jendrassik-Grof method to be relatively less affected by hemolysis and turbidity in the measurement of total bilirubin.
منابع مشابه
New kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.
A procedure has been developed for the automated measurement of conjugated bilirubin in serum with a centrifugal analyzer. The conjugated bilirubin is measured by a fixed time kinetic method which monitors the reaction between conjugated bilirubin and diazotized sulfanilic acid at 550 nm. Results are calculated based on a comparison of the reagent blank-corrected absorbance changes between 15 s...
متن کاملCentrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.
We describe two centrifugal analyzer methods for measuring total bilirubin in serum. Diazotized 2-chloroaniline-5-sulfonic acid is used in both. In the first procedure, ethylene glycol and methanol are used as an accelerator solvent; results correlate well with those by a Jendrassik and Grof method adapted to the centrifugal analyzer, but there is considerable hemolysis interference. In the sec...
متن کاملComparison of plasma creatinine determined with the Greiner Selective Analyser GSA II and the glomerular filtration rate.
1. Reference values for the plasma creatinine were established using the alkaline picrate method with the Greiner Selective Analyzer GSA II in relation to the Cr 51-EDTA Clearance. Individuals with normal GFR between 93 to 159 ml/min/1.73 m2 had creatinine values in men (n = 65) from 53.7 to 119.5 mumol/l (0.61 to 1.35 mg/100 ml) and in women (n = 59) from 37.7 to 107 mumol/l (0.42 to 121 mg/10...
متن کاملSingle-reagent method for rapid determination of total bilirubin with the "CentrifiChem" Analyzer.
We report a rapid single-reagent method for determining total bilirubin with the “CentrifiChem Analyzer” (Union Carbide Corp.). The reagent is the stable 1,5-disulfonate of diazosulfanilic acid, and ethylene glycol is used as an accelerator. The reaction requires less than 5 mm. Only 25 l of serum is needed. We present precision data ( = 2.62 mg/dl, SD = .082 mg/dl, CV = 3.13%) and results (r =...
متن کاملA new diazo method for the determination of bilirubin.
A new technic for the determination of total bilirubin is reported. The substitution of 2,4 dichloroaniline for sulfanilic acid results in a very stable diazotized reagent which reacts quickly with bilirubin in plasma or serum. Comparison with a sulfanilic acid procedure indicates that similar analytic values are obtained with this technic; short quality control studies indicate satisfactory pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 27 5 شماره
صفحات -
تاریخ انتشار 1981