Effects of vowel context on the recognition of initial and medial consonants by cochlear implant users.

نویسندگان

  • Gail S Donaldson
  • Heather A Kreft
چکیده

OBJECTIVE Scores on consonant-recognition tests are widely used as an index of speech-perception ability in cochlear implant (CI) users. The consonant stimuli in these tests are typically presented in the /alpha/ vowel context, even though consonants in conversational speech occur in many other contexts. For this reason, it would be useful to know whether vowel context has any systematic effect on consonant recognition in this population. The purpose of the present study was to compare consonant recognition for the /alpha, i/, and /u/ vowel contexts for consonants presented in both initial (Cv) and medial (vCv) positions. DESIGN Twenty adult CI users with one of three different implanted devices underwent consonant-confusion testing. Twelve stimulus conditions that differed according to vowel context (/alpha, i, u/), consonant position (Cv, vCv), and talker gender (male, female) were assessed in each subject. RESULTS Mean percent-correct consonant-recognition scores were slightly (5 to 8%) higher for the /alpha/ and /u/ vowel contexts than for the /i/ vowel context for both initial and medial consonants. This general pattern was observed for both male and female talkers, for subjects with better and poorer average consonant-recognition performance, and for subjects using low, medium, and high stimulation rates in their speech processors. In contrast to the mean data, many individual subjects demonstrated large effects of vowel context. For 10 of 20 subjects, consonant-recognition scores varied by 15% or more across vowel contexts in one or more stimulus conditions. Similar to the mean data, these differences generally reflected better performance for the /alpha/ and /u/ vowel contexts than for the /i/ vowel context. An analysis of consonant features showed that overall performance was best for the voicing feature, followed by the manner and place features, and that the place feature showed the strongest effect of vowel context. Vowel-context effects were strongest for the six consonants /d, j, n, k, m/, and /l/. For three of these consonants (/j, n, k/), the back vowels /alpha/ and /u/ produced substantially (30 to 35%) higher mean scores than the front vowel /i/. For each of the remaining three consonants, a unique pattern was observed in which a different single vowel produced substantially higher scores than the others. Several additional consonants (/s, g, w, b/, and /d/) showed strong context effects in either the initial consonant or medial consonant position. Overall, voiceless stop, nasal, and glide-liquid consonants showed the strongest effects of vowel context, whereas the voiceless fricative and voiceless affricate consonants were least affected. Consistent with the feature analysis, a qualitative assessment of phoneme errors for the six key consonants indicated that vowel-context effects stem primarily from changes in the number of place-of-articulation errors made in each context. CONCLUSIONS Vowel context has small but significant effects on consonant-recognition scores for the "average" CI listener, with the back vowels /alpha/ and /u/ producing better performance than the front vowel /i/. In contrast to the average results, however, the effects of vowel context are sizable in some individual subjects. This suggests that it may be beneficial to assess consonant recognition using two vowels, such as /alpha/ and /i/, which produce better and poorer performance, respectively. The present results underscore previous findings that poor transmission of spectral speech cues limits consonant-recognition performance in CI users. Spectral cue transmission may be hindered not only by poor spectral resolution in these listeners but also by the brief duration and dynamic nature of consonant place-of-articulation cues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between voice and speech perception in children with cochlear implant.

BACKGROUND The use of cochlear implant results in the optimization of speech perception, and, as a consequence in the development of oral language, speech and voice of its users, demonstrating to be one of the most effective and promising technologies to remedy hearing loss. However, little has been studied about the relationship between auditory skills and the voice of children using cochlear ...

متن کامل

Masking release and the contribution of obstruent consonants on speech recognition in noise by cochlear implant users.

Cochlear implant (CI) users are unable to receive masking release and the reasons are unclear. The present study examines the hypothesis that when listening to speech in fluctuating maskers, CI users cannot fuse the pieces of the message over temporal gaps because they are not able to perceive reliably the information carried by obstruent consonants (e.g., stops). To test this hypothesis, CI us...

متن کامل

The effect of reduced dynamic range on speech understanding: implications for patients with cochlear implants.

OBJECTIVE To determine the effect of reduced dynamic range on speech understanding when the speech signals are processed in a manner similar to a 6-channel cochlear implant speech processor. DESIGN Signals were processed in a manner similar to a 6-channel cochlear implant processor and output as a sum of sine waves with frequencies equal to the center frequencies of the analysis filters. The ...

متن کامل

بررسی اثر فیدبک شنوائی در تولید گفتار بعد از عمل کوکلئار ایمپلنت

The main goal of this study is to determine the auditory feedback effects in improvement of speech production process in prelingual totally deaf children who used cochlear implant prosthesis. For this reason, we recorded speech of four prelingual cochlear implant children pre and post of operation. Then we extract some static features of vowels-such as fundamental frequency, formant frequencies...

متن کامل

The effect of parametric variations of cochlear implant processors on speech understanding.

This study investigated the effect of five speech processing parameters, currently employed in cochlear implant processors, on speech understanding. Experiment 1 examined speech recognition as a function of stimulation rate in six Med-E1/CIS-Link cochlear implant listeners. Results showed that higher stimulation rates (2100 pulses/s) produced a significantly higher performance on word and conso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 2006