Determining the size and refractive index of microspheres using the mode assignments from Mie resonances.
نویسندگان
چکیده
A new method for determining the radius and refractive index of microspheres using Mie resonances is presented. Previous methods have relied on searching multidimensional space to find the radius and refractive index that minimize the difference between observed and calculated Mie resonances. For anything but simple refractive index functions, this process can be very time consuming. Here, we demonstrate that once the mode assignment for the observed Mie resonances is known, no search is necessary, and the radius and refractive index of best-fit can be found immediately. This superior and faster way to characterize microspheres using Mie resonances should supplant previous fitting algorithms. The derivation and implementation of the equations that give the parameters of best-fit are shown and discussed. Testing is performed on systems of physical interest, and the effect of noise on measured peak positions is investigated.
منابع مشابه
Enhanced coupling to microsphere resonances with optical fibers
Morphology-dependent resonances (MDR’s) of polystyrene microspheres were excited by an optical fiber coupler. For optical elimination of the air–cladding interface at the optical fiber coupler surface, the microsphere was immersed in an index-matching oil. MDR’s were observed, even though the relative refractive index between the microsphere and the oil was only 1.09. The observed MDR spectra a...
متن کاملDetermination of complex refractive index of polystyrene microspheres from 370 to 1610 nm.
We introduce an inverse method for determining simultaneously the real and imaginary refractive indices of microspheres based on integrating sphere measurements of diffuse reflectance and transmittance, and Monte Carlo modelling in conjunction with the Mie theory. The results for polystyrene microspheres suspended in water are presented.
متن کاملUniform approximation to Mie resonances
Uniform asymptotic approximations for the positions and widths of Mie resonances are reported . The results improve the accuracy of previous approximations, typically, by several orders of magnitude . They are suitable for fast numerical evaluation, allowing every resonance to be located well within its width, for all resonances of practical interest . The relative errors are very small even fo...
متن کاملResonances in Mie scattering by an inhomogeneous atomic cloud
Despite the quantum nature of the process, collective scattering by dense cold samples of two-level atoms can be interpreted classically describing the sample as a macroscopic object with a complex refractive index. We demonstrate that resonances in Mie theory can be easily observable in the cooperative scattering by tuning the frequency of the incident laser field or the atomic number. The sol...
متن کاملWhispering Gallery Modes in Standard Optical Fibres for Fibre Profiling Measurements and Sensing of Unlabelled Chemical Species
Whispering gallery mode resonances in liquid droplets and microspheres have attracted considerable attention due to their potential uses in a range of sensing and technological applications. We describe a whispering gallery mode sensor in which standard optical fibre is used as the whispering gallery mode resonator. The sensor is characterised in terms of the response of the whispering gallery ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 32 11 شماره
صفحات -
تاریخ انتشار 2015