Influence of size and CCD-angle of a short stem hip arthroplasty on strain patterns of the proximal femur - an experimental study.
نویسندگان
چکیده
PURPOSE The number of primary total hip arthroplasties (THA) is steadily increasing. Over the last decade numerous so-called short stem hip arthroplasties were introduced on the market. The aim of these implants with a predominantly metaphyseal anchorage is to reduce stress shielding and thereby the risk of aseptic loosening. One of the short stem arthroplasties with predominant metaphyseal fixation is the METHA® short stem (Aesculap, Tuttlingen, Germany). In order to reconstruct the biomechanics the METHA stem is available in different sizes with different centrum-collum-diaphysis-angles (CCD-angle). In this study, we want to address the research question of how the size of the implant and different CCD-angles influence the strain patterns of the proximal femur. METHODS Three different stem sizes (size 2, 3 and 4 - CCD-angle 130°) and three stems with different CCD-angles (size 3 - 120°, 130° and 135° CCD-angle) were successively implanted in a synthetic femur. Eight strain gauges monitored the corresponding strain patterns of the proximal femur. RESULTS Independent of stem size and CCD-angle only small changes in the strains were recorded around the distal part of the METHA stem when compared to the intact femur. However, all stems increased the strains in the region of the calcar. This was most pronounced by smaller CCD-angles and major sizes. CONCLUSION The stem size and CCD-angle primarily influence the region of the calcar. Greater sizes and smaller CCD-angles lead to increased strains at the calcar. The other regions are hardly influenced by the stem size and CCDangle of the femoral component.
منابع مشابه
Bone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملAnalysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases
Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...
متن کاملEffects of Hip Geometry on Fracture Patterns of Proximal Femur
Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF), intertrochanteric (ITF) and Subtrochanteric (ST...
متن کاملChallenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta of bioengineering and biomechanics
دوره 19 1 شماره
صفحات -
تاریخ انتشار 2017